2.2 - Dryer Setup
Once unbolted from the pallet, installation requires only electrical connections, pneumatic air
line connection and intake and output material lines to be connected.
2.2.1 - Compressed Air Connection
Connect an air supply to the air regulator’s IN port using a
male ¼ ” NPT fitting.
An operating air pressure of 80 psi (5.5 bar) while the
vacuum generator is running is required for proper
operation of the Dryer.
If your air supply has oil in it, add an oil separator
(coalescing filter).
Oil in the air will combine with dust drawn from the canisters forming a paste
inside the vacuum generator. It will stop working and require cleaning.
Observe the air pressure gauge to be sure the pressure maintains 80 psi (5.5 bar)
while the vacuum generator is running as you check and adjust the regulator. If
pressure drops below 80 psi, adjust the regulator. If the pressure cannot be
maintained at 80 psi (5.5 bar) while the vacuum generator is running, then the air
supply line is not adequate.
Do not supply Dryer with a lubricated air supply.
Damage to Dryer may result. Use only a clean,
dry, oil-free air supply.
Summary of Contents for VBD-50
Page 2: ...Maguire Products Inc Edition May 27 2009 VBD 50 2 VBD Vacuum Batch Dryer...
Page 14: ...Maguire Products Inc Edition May 27 2009 VBD 50 14 VBD Vacuum Batch Dryer 3 4 Dryer Overview...
Page 36: ...Maguire Products Inc Edition May 27 2009 VBD 50 36 VBD Vacuum Batch Dryer 6 3 VBD 50 Diagrams...
Page 37: ...Maguire Products Inc Edition May 27 2009 VBD 50 37 VBD Vacuum Batch Dryer...
Page 38: ...Maguire Products Inc Edition May 27 2009 VBD 50 38 VBD Vacuum Batch Dryer...