Load Cell Calibration
Displays shown here are in full grams. MB, 100 and 200 series models are in 1/10 grams, with
a decimal.
If your load cells already display a weight close to zero, plus or minus 10 grams, you may skip this section and go
directly to:
TURNING ON OUTPUTS (next page).
If your unit DOES NOT display an acceptable weight, you should recalibrate them, that is reset your ZERO weight, at
this time.
To do so:
BE SURE
the weigh bin is EMPTY.
BE SURE
the load cell plug is plugged into the side of the controller.
BE SURE
the weigh bin is resting on the load cells freely.
BE SURE
the air line to the dump valve is connected as it would be during normal operation. A disconnected
air line adds weight.
BE SURE
The load cells and bin are not jammed in any way. To test for this see that a light touch on the bin
causes the display to change. When the pressure is removed the display must return to exactly
where it was, plus or minus 1 gram.
If this does not happen, something is touching something and the bin is not entirely free to move.
Check EVERYTHING around the bin.
LOAD CELL CALIBRATION:
The sequence of keystrokes is as follows:
Load Cell Zero Calibration Keypad Sequence:
Press
OPTIONS
Display will say:
ENTER PASSWORD
Press
then, press Enter
Display will show menu options
Press
SPECIAL FUNCTIONS
Display will show menu options
Press
SETUP
Display will show menu options
Press
Calibrate Load Cells
Press
SET ZERO WT
Display will say: Confirm weigh bin is empty then press:
YES
(weigh bin can be dumped using DUMP BIN button).
Followed by a gram weight of
0
Press
Display will say:
WAITING
The ZERO point of the load cells is now set properly. FULL weight calibration may also be done at this time, however,
it probably is NOT NECESSARY. When load cell readings shift due to rough handling, the entire range of readings
from ZERO to FULL shift together. The ZERO weight calibration routine resets the full range of the cells and,
therefore, corrects FULL weight readings as well. For information on FULL weight calibration, see RECALIBRATION
OF LOAD CELLS.
PROCEED TO:
TURNING ON OUTPUTS
and MATERIAL TYPES
NEXT PAGE
Summary of Contents for Weigh Scale Blender WSB
Page 2: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 2 W E I G H S C A L E B L E N D E R...
Page 9: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 9 W E I G H S C A L E B L E N D E R...
Page 13: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 13 W E I G H S C A L E B L E N D E R...
Page 84: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 84 W E I G H S C A L E B L E N D E R...
Page 85: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 85 W E I G H S C A L E B L E N D E R...
Page 86: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 86 W E I G H S C A L E B L E N D E R...
Page 87: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 87 W E I G H S C A L E B L E N D E R...
Page 88: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 88 W E I G H S C A L E B L E N D E R...
Page 89: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 89 W E I G H S C A L E B L E N D E R...
Page 90: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 90 W E I G H S C A L E B L E N D E R...
Page 91: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 91 W E I G H S C A L E B L E N D E R...
Page 92: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 92 W E I G H S C A L E B L E N D E R...
Page 93: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 93 W E I G H S C A L E B L E N D E R...
Page 94: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 94 W E I G H S C A L E B L E N D E R...
Page 95: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 95 W E I G H S C A L E B L E N D E R...
Page 96: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 96 W E I G H S C A L E B L E N D E R...