VL-VLP IM 19 JUNE 2017 © 2017 NOVATEC, Inc. All Rights Reserved
Page 19
5.
Reinstall new brush into motor housing and replace the retaining clip. Be sure to
properly seat the nub on the bottom of the brush holder into the motor housing
groove.
6.
Repeat steps 2 thru 5 for the adjacent brush.
7.
Replace the plastic shield on top of the motor by aligning it on top of the motor and
pushing down until the spring clips on each brush snap into place.
8.
Reinstall metal cover over motor.
11.6- MOTOR REPLACEMENT
Disconnect all power from the loader system. Disconnect the motor wiring from the junction
box located on the lid of the chamber. Remove the three springs that clamp the motor to the
lid. The motor can now be removed. Check the gasket that seals the vacuum motor to the
lid and renew if necessary. Reverse the above steps to install the vacuum motor. Connect
power and verify that the system is operating correctly.