63
BA023001-en
6.4.2
Carry out brake test with automatic sequence
A computer with monitor, a TV or a SmartDevice is required for operation.
Test sequence without remote control
(automatic sequence selected)
Status line*: "Please drive on test equipment"
Drive on test rollers
(both sensing rollers are actuated)
Automatic roller start
(approx. 3 seconds after sensing roller actuation)
Status line*: “Please brake”
Brake up to maximum brake force, then release brake again or brake
until the wheels lock up (slippage).
Rollers stop if slippage occurs!
The indicators move to the max. brake values.
Exit while test rollers are running (directly while rollers are still run-
ning or when they start up again approx. 3 seconds after restarting)
Axle change, new measurement can begin.
*In conjunction with monitor display