3.6 Manual
Lowering
In case of motor defect or power failure the lift can be lowered manually. The lift may only be
lowered, not raised.
Authorized personnel only! Do not restart the lift before the error has been remedied.
1
Open the solenoid valve first at the slave
side cylinder (Y5), then at the master
side cylinder (Y4).
2
Position the slide shoes under the
latches at both cylinders.
The slide shoes prevent the latches from
engaging the toothed rack.
3
Push the lowering valve (Y2) at the
hydraulic power unit.
Lift begins to lower slowly.
4
Once the error has been remedied, raise
the lift without load and close the
solenoid valves finger tight.