22
BA081101-en
3.7
Manual Lowering (Lift with Center Cover)
In case of motor defect or power failure the lift can be lowered manually. The lift may only be
lowered, not raised.
Authorized personnel only! Do not restart the lift before the error has been remedied.
1
Open the solenoid valve (A) first at
the slave side cylinder (Y5), then at
the master side cylinder (Y4).
2
If required, disengage the safety latches from
the toothed rack using the hand pump (B).
3
Position the slide shoes (C) under
the latches to prevent them from
engaging the rack.
4
Remove the hose (D) from the control unit and
push it against the nozzle of the compressed-
air gun (E).
5 To lower the lift, pull the trigger. To stop the lift, release the trigger and remove the hose from
the gun nozzle.
A
B
C
D
E