5.13
Bleeding the Cylinders
Pos: 106 /Produktfamilien/Hebetechnik/- Archiv -/00 Hebetechnik Alle/Inhalte/Warnung!/Inhalt: WARNUNG - Entlüften unter Last verboten_12pt @ 55\mod_1549978883386_75.docx @ 3117333 @ @ 1
WARNING
Do not bleed the hydraulic system under load.
Pos: 107 /Produktfamilien/Hebetechnik/SQUARE/322301 ZS SQUARE II/BA/Inhalt: 3223 Hubzylinder entlüften ZS SQUARE I+II (Text) @ 27\mod_1327997150455_75.docx @ 1523807 @ @ 1
The bleeder screws (A) are located between the attachment screws of the
superstructure and can be accessed through a drill hole.
If the lift is equipped with runways and wheel-free jack, the WFJ must be fully
raised to make the bleeder screws accessible.
1 Raise the lift about half way up.
2 Remove the sealing plugs and open the bleeder screws (A) on both cylinders
1 turn max.
3 When fluid comes out free from air, close the screws and torque to 50 Nm.
4 Insert the sealing plugs.
5 Lower lift to bottom position and check fluid level of reservoir, top up as
required.
Pos: 108 /Produktfamilien/Hebetechnik/SQUARE/322301 ZS SQUARE II/BA/Inhalt: 3223 Hubzylinder entlüften (Bild) @ 23\mod_1296637413381_0.docx @ 969103 @ @ 1
Pos: 109 /-----Format-----/Seitenumbruch @ 0\mod_1134403577687_0.docx @ 1277 @ @ 1
A