en
8 | ACX2180H |
2.5
Safety devices
Description
Function
Pressure
switch
Switches the compressor off in the normal operating
pressure is exceeded
Safety valve The safety valve opens if the design pressure is exceeded
Circuit
Breaker
Interrupts the power supply if overcurrent is applied to the
ACX2180H
Vents
The ACX2180H is provided with vents in the housing to
ensure the exchange of air even when switched off.
2.6
Proper disposal
At the end of its service life, this equipment must be
disposed of as follows:
—
Contact the service center to have the refrigerant in
the unit recovered and recycled.
—
Consign the unit to an authorized collection
center according to local legislation.
2.7
Recycled material disposal
—
Return the refrigerant recovered from the
unit to the refrigerant supplier for proper
disposal or recycling.
—
Lubricants extracted from the vehicle's
A/C system must be returned to an official
oil collection center
2.8
Packaging disposal
Electronic and electrical A/C service
equipment must never be disposed of with
domestic waste, but recycled appropriately.
—
The packaging must be disposed of in
conformity with local legislation.
—
This contributes to protecting the
environment
2.9
Disposal of combo filter
—
Dispose of the filter via official collection
points or in accordance with the local
regulations. This contributes to protecting
the environment
2.10
Technical Data
Description
Specification
R134a tank capacity
12L
Service pressure
400PSI
Maximum content
22lbs.
Method to weigh gas content
Load cell
Recovered oil container
250ml
Vacuum pump
2CFM dual stage
Vacuum pump oil quantity
250ml
Compressor capacity
0.87cu in/14cc
Dryer filter
90kg recovered R134a
Non-condensable gas purge
Automatic via solenoid valve
HP and LP taps
Automatic
Display
7 inch capacitive touch screen
Software updating
USB type A or USB type B direct
connect to PC
Printer (optional)
Thermal, 24 columns
All functions
Automatic and manual
Recycling mode
Single pass
Memory for customized cycles
100 records
Flushing
With integrated solenoid valves
System pressure diagnostics
Manual and automatic
Dryer filter replacement alarm
Active
Vacuum pump oil replacement
alarm
Active
Full/empty tank check alarm
Active
Full oil container check alarm
Visual
Empty oil container alarm
Visual
Dimension H x W x D
119 x 74 x 74 cm
Dry weight
98kg
Power supply frequency
60Hz
Voltage
120VAC, 1 phase
Total max load
7.5A
Overcurrent protection
12A (circuit breaker)
Operating temperature
50 - 122°F
Humidity
10 90%RH (non-condensing)
Storage temperature and
humidity
-13 to 50°F
10 - 90%RH (non-condensing)
Max operating altitude
6562 ft.
Pollution degree
2
Water degree
0
Certifications
SAE J2788
UL 1963
CAN/CSA STD C22.2NO. 120
– M91
2.11
Glossary
Recovery phase:
The refrigerant is extracted from the vehicle
air conditioning system, cleaned and routed into the internal
bottle of the ACX2180H. The refrigerant oil collected in the
process is drained into the used oil bottle at the ACX2180H.
Vacuum phase:
A vacuum is generated in the vehicle air con-
ditioning system. Measurement of the drop in pressure begins as
soon as the vacuum has been generated.
Charging phase:
A certain quantity of refrigerant is added to the
vehicle air conditioning system.
Summary of Contents for ACX2150
Page 1: ...MAHLE ACX2180H...
Page 2: ...en 2 ACX2180H...