L A D E N M Ü H L E N
S H O P G R I N D E R
Defect
The grinder does
not start.
*
115V / 60Hz only
Defect
Grinder rotates but
without grinding.
In case of other malfunctions or continued faults, please contact your
dealer or your authorised customer service centre.
Cause
The power supply
plug is not inser-
ted.
The overload cir-
cuit breaker has
been tripped.
The motor protec-
tor was tripped.*
The pre-fuse was
tripped.
Cause
Carrier breakage.
Metal parts on the
hopper magnet
obstruct the inco-
ming flow of ma-
terial to be ground.
Remedy
Insert the plug into the out-
let.
Check to determine wheth-
er the reset button of the
circuit breaker has jumped
out. Press the reset button
in again if appropriate. In
case of repeated tripping of
the circuit breaker, contact
your authorised customer
service centre or dealer.
Give the grinder a cooling-
off break of at least 100
minutes (para. 4).
Check the pre-fuse. Restore
the pre-fuse to its initial
state or replace it. Deter-
mine whether other con-
suming devices are also
connected to this fuse.
Remedy
Remove the grinder casing
cover, take out the broken
pieces of the driver, insert a
new driver and then install
the grinder casing cover
again.
Clean the hopper magnet.
page 9