6 Technical data
20
5.6 Unit versions
Unit
ver-
sions
Start
delays
[ sec.]
Over-
run
time
[min.]
Mains
cable
[mm²]
4 op-
erat-
ing
pro-
grams
speed
con-
trol-
lable
ECA
100
ipro
5 x 1.5
●
ECA
100
ipro
VZC
0/
50
/90/
120
0/
8
/17/
25
5 x 1.5
●
ECA
100
ipro F
0
/50/90/
120
0/
8
/17/
25
3 x 1.5
●
ECA
100
ipro H
0/
50
/90/
120*
8
/17/2
5**
3 x 1.5
■
ECA
100
ipro B
0/
8
/17/
25
3 x 1.5
●
ECA
100
ipro K
5 x 1.5
■
●
ECA
100
ipro
KVZC
0/
50
/90/
120
0/
8
/17/
25
5 x 1.5
●
ECA
100
ipro KF
0
/50/90/
120
0/
8
/17/
25
3 x 1.5
●
ECA
100
ipro KH
0/
50
/90/
120*
8
/17/2
5**
3 x 1.5
■
ECA
100
ipro KB
0/
8
/17/
25
3 x 1.5
●
Bold
Delivery status
● Standard equipment
■ With optional light switch
* Start delay available when using an optional
switch (e.g. light switch).
** Overrun time of 0 min available when using an
optional switch (e.g. light switch).
6 Technical data
6.1 Ambient conditions
• Permissible maximum temperature of air me-
dium + 40 °C.
• Resistance to interference according to EN
55014-2 depending on pulse shape and energy
component 1000 to 4000 V. If operating with
fluorescent tubes, extra interference suppres-
sion measures are needed (L or C components
or RC modules, protection diodes, varistors) be-
cause these values may be exceeded.
• Recommendation: When operating on switches
with a glow lamp, wire an X2 capacitor (220
nF/250 V) to zero. The capacitor is to be
provided by the customer.
• Storage: Store unit exclusively in a dry location
(-20 to +50 °C).
6.2 Technical data table
Rated voltage
230 V
Power frequency
50 Hz
Sound pressure level
Level 1: 27 dB(A)
Level 2: 32 dB(A)
Degree of protection
IP X5
Weight
0.7 kg
For more technical data → rating plate.
For characteristic curves → www.maico-ventil-
atoren.com.
7 Mounting preparations
7.1 Wall
Use mounting material suitable for base and of
sufficient dimensions. Ensure sufficient supply air.
The prescribed minimum distances to the
wall and the ceiling shown in the figure must
be observed.