VENTILATOREN
FR
AP 100/100 B/120/150
SG 100/100 B/120/15
DE
UK
5. Push the AP shutters/SG external grilles
with the flange into the wall sleeve and
screw to the wall with 4 screws. Ensure the
correct position of the sealing strip. Note
the installation position: with Maico letter
-
ing on the bottom right.
6. AP/SG 100/100 B/120: If necessary, insert
optional fly screen FG into the shutter/the
external grille.
7. AP/SG 100/100 B/120: Press the housing
unit onto the receptacle so that it audibly
engages in the 4 locking tabs.
8. Seal the AP shutters/the SG external grille
to the wall in a manner that is permanently
elastic and weatherproof. Suitable sealing
material (silicon) is to be provided by the
customer.
9. Run function test.
7
Cleaning
If necessary, clean the AP shutter/SG external
grille with a dry cloth. Frequency depends on
ambient conditions and anticipated impair
-
ments.