background image

INSTALLATION INSTRUCTIONS

ECA 100 ipro KVZC

Version: 2016-06-24 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice

Page 5

EV - Start delay

SB - Switch operation

NZ - Overrun time

Wall mounting of ECA small room fans

Please note the following points when fitting ECA 100 ipro, ECA 150 ipro, ECA piano and ECA 120 series model fans in a

wall:

A minimum distance between the wall and the ceiling must be observed when preparing the wall breakthrough, see dia-

gram.

Fit a wall sleeve.

Feed in the connecting cable for surface or recessed mounting.

ECA 100 ipro and ECA piano only available as recessed-mounted fans.

Secure the fan using screws during installation.

The AP shutter prevents cold air from entering when the fan is switched off. Not required with ECA piano and all versions

with electrically-operated internal shutter.

1

ECA fan

2

WH wall sleeve

3

AP outside shutter

4

Masonry

5

Plaster

6

Cable entry

Ceiling installation with roof cowl

Please note the following points when fitting ECA 100 ipro, ECA 150 ipro, ECA piano and ECA 120 series model fans in a

ceiling in ventilation systems with a roof cowl:

Reviews: