 4. Safety instructions and warnings 

 

10 

Risk of death from carbon monoxide 

when operating with air-ventilated 

fireplaces. 

When operating with air-

ventilated fireplaces and in 

"air extraction" 

installation position

, a sufficient fresh air 

supply must be ensured.  The maximum 

permitted pressure difference per living unit is 

4 Pa. The consent of a professional chimney 

sweep is needed in all cases. 

 

Danger of electric shock from 

operating with the unit not fully 

mounted.

 Before taking off the terminal 

box cover, shut down all supply circuits 

(switch off mains fuse), secure against being 

accidentally switched back on and position a 

visible warning sign. Only operate the fan 

when it is completely installed. 

 

Danger if the relevant regulations for 

electrical installations are not 

observed. 

 Before installing the electrics, shut down 

all supply circuits, deactivate the mains fuse 

and secure it so it cannot be switched back 

on. Attach a warning sign in a clearly visible 

place. 

 Be sure to observe the relevant regula-

tions for electrical installation; e.g.  

EN 50110-1, in Germany this is particularly 

VDE 0100, with the corresponding parts. 

 A mains isolation device with contact 

openings of at least 3 mm at each pole is 

mandatory. 

 Only connect unit to a permanently wired 

electrical installation with NYM-O / NYM-J, 3 

x 1.5 mm² or 5x 1.5 mm² (depending on unit 

type) cables. 

 The units may only be operated using the 

voltage and frequency shown on the rating 

plate. 

 The degree of protection stated on the 

rating plate is only guaranteed if installation is 

undertaken correctly and if the connection 

cable is correctly guided through the cable 

grommet(s). The grommets must tightly seal 

the cable sheathing. 

 Check protective-conductor opening on 

housing. 

 Unit may be energized even when at a 

standstill and may be switched on 

automatically by sensors, such as for time 

delay or humidity etc. Maintenance and fault 

finding only permissible when carried out by 

trained specialists. 

 

Exercise caution when handling 

packaging materials. 

 Observe applicable safety and accident 

prevention requirements. 

 Store packaging material out of the reach 

of children. 

 

5. Operation  

Fan is switched on/off with light switch or 

separate switch (both to be supplied by the 

customer). The fan switches on/off 

immediately when the switch is pressed. 

 

In the event of thermal overload, the 

integrated motor overload protection 

switches the unit off. Before starting 

the fan back up leave it switched off 

long enough for the motor and 

temperature limiter to cool down. 

Only then switch it back on. 

 

6. Technical data 

Rated voltage 

230 VAC 

Power frequency 

50 Hz 

Sound pressure level  45 to 57 dB(A)* 
Degree of protection 

IP 44 

Weight 

2 to 5 kg* 

* Depending on unit variant

 

For more technical data, 

 rating plate. 

For dimensions, 

 fold-out page. 

 

7. Environmental conditions and 

operating limits 

Maximum permitted temperature of the air 

medium: + 40 °C 

Summary of Contents for EN 25

Page 1: ...Wandeinbauventilatoren Mounting and Operating instructions Wall mounted fans Instructions de montage et Mode d emploi Ventilateurs muraux encastrables EN 20 EN 25 EN 31 ENR 20 ENR 25 ENR 31 www m aic...

Page 2: ...EN ENR Abmessungen Dimensions A B C D E EN 20 55 103 212 320 268 EN 25 55 103 266 370 315 EN 31 60 126 320 445 375 ENR 20 55 103 212 320 268 ENR 25 55 103 266 370 315 ENR 31 60 126 320 445 375...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ...chulung und Erfahrung die einschl gigen Normen und Richtlinien kennen die elektrischen Anschl sse gem beigef gtem Verdrahtungsplan fachgerecht und sicher ausf hren k nnen und Risiken und Gef hrdungen...

Page 7: ...igen und warten lassen welche die Gefahren dieser Arbeiten sicher erkennen und vermeiden k nnen Verletzungsgefahr durch Saugwirkung des Ventila tors und drehendes Fl gelrad Haare Kleidung Schmuck etc...

Page 8: ...x 1 5 mm je nach Ger tetype anschlie en Ger te nur mit auf Typenschild angege bener Spannung und Frequenz betreiben Die auf dem Typenschild angegebene Schutzart ist nur gew hrleistet bei bestim mungsg...

Page 9: ...inzelnen Adern gem Schaltbild in Kapitel 17 verdrahten 10 Montage 10 1 Wandmontage Abb 2A bis 2H 1 Netzsicherung ausschalten gegen Wiedereinschalten sichern und ein Warnschild anbringen 2 D bell cher...

Page 10: ...alten Funktionstest durchf hren 10 2 Deckenmontage ohne Abb 1 Den Deckeneinbau wie unter Wandeinbau beschrieben vornehmen 2 Innenabdeckung 1 an Position B vor sichtig und mit geeignetem Bohrer 3 5 mm...

Page 11: ...im Ge h use durch staubhaltige Luft Elektrofachkraft hinzu ziehen Innenraum auf keinen Fall mit Wasser oder Hochdruckreiniger reinigen Besteht die St rung weiterhin oder tritt diese wiederholt auf de...

Page 12: ...standards and guidelines can competently and safely connect units to an electrical power supply in line with the attached wiring diagram and are able to recognise and avoid risks and dangers associate...

Page 13: ...associated with this work Danger of injury due to suction from fan and rotating impeller Hair clothing jewellery etc may be pulled into the fan if you get too close to it During operation always keep...

Page 14: ...n unit type cables The units may only be operated using the voltage and frequency shown on the rating plate The degree of protection stated on the rating plate is only guaranteed if installation is un...

Page 15: ...wire the individual cable cores in accordance with the wiring diagram in Chapter 17 10 Mounting 10 1 Wall mounting Figures 2A to 2H 1 Switch off mains fuse secure against being accidentally switched...

Page 16: ...twist it 15 Switch the mains fuse on Run function test 10 2 Ceiling mounting not shown 1 Carry out the ceiling installation as described in the wall mounting section 2 Drill through the internal cove...

Page 17: ...nces should the inside of the unit be cleaned with water or a high pressure cleaner If the fault still continues or occurs again disconnect the fan from the power supply at all poles Let a certified e...

Page 18: ...ssances et d exp rience dans la technique de ventilation est autoris effectuer le montage Les travaux sur le syst me lectrique ne doivent tre ex cut s que par des lectriciens qualifi s On entend par l...

Page 19: ...sont diffus s dans les pi ces par le ventilateur Ne jamais utiliser le ventilateur pour diffuser des produits chimiques ou gaz vapeurs agressifs Des vapeurs de graisse et d huile en provenance de hot...

Page 20: ...d alimentation lectrique d sactiver le fusible secteur s curiser contre toute remise en service intempestive et apposer un panneau d avertissement de mani re bien visible N utiliser le ventilateur qu...

Page 21: ...ionnement en raison du frottement de l h lice 8 Installer le manchon d assemblage 3 ni gauchi ni coinc Pr voir un support plan Risque de court circuit Endommage ment de l appareil par formation de con...

Page 22: ...rnier Pour que l humidit ne puisse pas rentrer dans le bornier percer le manchon en rond un peu plus petit que le c ble de raccordement Le manchon de c ble doit enserrer troitement le c ble de raccord...

Page 23: ...Dommage sur le capot int rieur si celui ci est nettoy dans un lave vaisselle Ne pas nettoyer le capot int rieur dans un lave vaisselle 1 Retirer le capot int rieur 1 aucun outil n est n cessaire 2 Net...

Page 24: ...ndiquer les donn es suivantes 1 N d impression du pr sent mode d emploi 0185 0992 0004 2 N de plaque signal tique X sur le c t de la plaque 3 N de position selon la figure 1 Adresse de commande Maico...

Page 25: ...ity controller Cable only for MK shutter Marche Arr t par interrupteur thermostat TH hydrostat HY5 r gulateur de la qualit par l air EAQ Conducteur uniquement pour trappe MK EN 20 EN 25 EN 31 DE Mit 5...

Page 26: ...hutter S1 Marche Arr t S2 Commutation extraction d air a ration Borne 5 extraction d air Borne 6 a ration Conducteur uniquement pour trappe MK ENR 20 ENR 25 ENR 31 DE Mit Stufen Wendeschalter FS6 FS7...

Page 27: ...K ENR 20 ENR 25 ENR 31 DE Mit 5 Stufentransformator TRE und Wendeschalter W1 WU1 UK With TRE 5 step transformer and W1 WU1 reversing switch FR Avec transformateur 5 plots TRE et commutateur inverseur...

Page 28: ...ormator TRE S und 5 Stufenschalter ESS 20 UK With TRE S 5 step transformer and ESS 20 5 step switch FR Avec transformateur 5 plots TRE S et commutateur 5 plots ESS 20 TRE S ESS 20 S1 TRE S 5 Stufentra...

Reviews: