6 Technical data
34
ER-A
ER-AK
ER-AH
ER-AB
Adjustable interval control for ventilating rooms that are
not regularly used. Time interval can be set for
0
*, 1, 2, 4,
6 or 12 hours, 10 min. operating time per interval
●
●
●
Interval control can be switched off.
●
●
●
Switching option: The base load can be switched on or
off by an additional switch (Wiring diagrams).
●
●
●
●
* Factory setting: Tolerance of time details max. ±
5 %
** For the
ER-AB
, the start delay only affects the
light switch operation.
*** For
ER-AH
humidity control in full load, 40 m³/
h, 60 m³/h and 100 m³/h can be set.
6 Technical data
6.1 Environmental conditions and op-
erating limits
• Permissible maximum temperature of air me-
dium + 40 °C.
• The air supply to the home must be set up so
that virtually no air can flow into the living areas
from the kitchen, bathroom or WC.
• A room from which the air is to be extracted
must be fitted with a non-closable, free supply
air cross section of at least 150 cm², e.g. with
MLK door ventilation grille.
•
ER EC
units have resistance to interference in
line with EN 55014-2 (depending on pulse type
and an energy component of 1000 to 4000 V).
These values can be exceeded when operating
with fluorescent tubes. In this case, additional
interference suppression measures (L, C or RC
modules, protection diodes, varistors) are re-
quired.
6.2 Regulations for operation with
fireplaces
Sufficient supply air intake
must be ensured
during operation with
air-ventilated fireplaces
.
The maximum permitted pressure difference per
residential unit is 4 Pa.
The unit may only be installed in residential units
with air-ventilated fireplaces under the following
conditions:
• the evaluation criteria drawn up by the respons-
ible, regional master chimney sweep are met;
• Parallel operation of air-ventilated fireplaces for
liquid or gaseous fuels and air-extracting equip-
ment can be prevented using safety devices or
• the extraction of exhaust gas from the air-ventil-
ated fireplaces is monitored by special safety
devices. The ventilation system or the fire-
places must be switched off if the equipment is
triggered.
6.3 Technical data table
Rated voltage
230 V
Power frequency
50 Hz
Power consumption
ER EC
and
ER-A
3/5
W*
ER-AH
,
ER-AK
,
ER-AB
2/2.5/
3/5
/17W*
Degree of protection
IP X5
Sound pressure level
L
WA7
19 to 52 dB(A)
Mains cable
to
ER EC
,
depending on switching
variant for
ER-A
,
ER-
AH
,
ER-AK
,
ER-AB
3 x 1.5 mm²
or
5 x 1.5 mm²
Weight
Housing
0.6 kg
Fan insert
0.72 kg
Cover
0.6 kg
* Specification according to DIN 18017-3 with an
equivalent absorption area of A
L
= 10 m²
For more technical data → rating plate.