8 Housing installation
44
DANGER Fire may spread if connection
duct is incorrectly installed.
Only use permitted duct material (
Correctly attach connection duct to exhaust
socket.
6. Connect connection duct to exhaust socket
sealed for ventilation, e.g. with cold-shrink
tape.
7. Provide unit with electrical connection:
trically connecting the unit [
8. Insert the plaster protective cover in the hous-
ing.
9. Plaster in housing flush with front edge.
8.6 Wall installation, second room
Installation video for ER EC second room con-
nection
1. Cut out housing segment on the marking using
a knife.
NOTICE The unit will be damaged/function
will be impaired by incorrect air if the installa-
tion socket is inserted incorrectly [11.1].
Degree of protection is no longer guaranteed.
Correctly insert installation socket up to stop.
This must audibly engage.
2. Place installation socket in housing. The edge
of the socket must click into place on the wall
of the housing.
3. Install housing as described above for
single
room
.
4. Connect suction duct with installation socket
sealed for ventilation.
5. Produce fixing holes for adapter and insert
dowels.
6. Connect adapter to suction duct, e.g. with
cold-shrink tape.
7. Secure adapter to the wall.
8. Insert filter mat and locate the internal grille in
the correct position.
11.1 Installation socket for second room extrac-
tion, DN 75/80
11.2 Adapter
11.3 Internal grille
11.4 G2 filter mat