12. Electrical connection
24
12. Electrical connection
16 Power cable
32 Stepped grommet
34 Terminal block
CAUTION
Risk of damage to unit in the event of
short-circuits.
Cut off and insulate PE
conductor and individual cable cores that
are not required!
NOTICE
Damage to the unit if connected
incorrectly. For example, if an electric
load is connected to terminal 4 or if
connected to 2 phases.
Connect the unit as shown in the wiring
diagrams in chapter 12. Do not connect
additional consumers to terminal 4.
DANGER
Danger from electric shock/unit damage
if installed incorrectly with a power
cable that is too long.
If the cable feed is
too long inside the housing, the fan insert
cannot be installed correctly. The power
cable may be damaged when inserting the
fan insert.
Area for mains connection
labelled: Lay wires according to the
contour.
Note that the maximum spacing
to the terminal box is 11 cm. Do not cut the
power cable inside the housing too short.