13 System and accessory com-
ponents
13.1 System components
ER EC fan insert
Article no. 0084.0360
• Fan insert for installation in ER GH flush-moun-
ted/surface-mounted housing. Air volume 30
m³/h, 60 m³/h. In combination with an intelligent
cover for the base load and full load, further
volumetric flows can be set (see covers).
• Air outlet adapter with air outlet facing upwards
(factory setting).
• Air outlet adapter with air outlet facing the rear
(can be converted without tools).
ER-A cover
Article no. 0084.0361
• Standard model
• Air volume 30 m³/h, 60 m³/h
• Installation and operating instructions for ER
covers
ER-AK cover
Article no. 0084.0362
• Comfort version with intelligent time module
• Air volume 30 m³/h, 60 m³/h according to fact-
ory setting. Further volumetric flows that can be
set: base load: 20 m³/h, 30 m³/h, 40 m³/h, 60
m³/h or 100 m³/h, full load: 20 m³/h, 30 m³/h, 40
m³/h, 60 m³/h or 100 m³/h
• Installation and operating instructions for ER
covers
ER-AH cover
Article no. 0084.0363
• Model with humidity control and intelligent time
module
• Air volume 30 m³/h, 60 m³/h according to fact-
ory setting. Further volumetric flows that can be
set: base load: 20 m³/h, 30 m³/h, 40 m³/h, full
load: 60 m³/h, 100 m³/h
• Installation and operating instructions for ER
covers
ER-AB cover
Article no. 0084.0364
• Model with motion detector and intelligent time
module
• Air volume 30 m³/h, 60 m³/h according to fact-
ory setting. Further volumetric flows that can be
set: base load: 20 m³/h, 30 m³/h, 40 m³/h, 60
m³/h, 100 m³/h, full load: 20 m³/h, 30 m³/h, 40
m³/h, 60 m³/h, 100 m³/h
• Installation and operating instructions for ER
covers
13.2 Accessory components
UPM 60/100 mounting support
Article no. 0018.0010
• For fastening the ER GH housing with mounting
screws.
ER-UPM mounting support
Article no. 0093
• For fastening the ER GH housing with hammer
head screws or mounting screws.
ER-ZR second room connection set
Article no. 0093.1025
• Comprising internal grille, filter mat adapter,
and plastic exhaust socket.
ER-AS extraction socket (DN 70)
Article no. 0093.0928
• For connecting a toilet seat air extraction unit
(DN 70), extraction via flushing pipe.
ER-MO expanded rubber set
Article no. 0092.0361
• For sound insulation of the ER GH flush-moun-
ted housing.
ER-MS installation kit
Article no. 0093.0603
• For installation of the ER GH flush-mounted
housing, consisting of 4 hammer head screws,
4 nuts and 90° brackets.
ER-MR EC wall frame
Article no. 0192.0765
• For housings that have been plastered or
mounted too deeply.