12. Installation ‒ ER-UP/G - single room
22
2 Exhaust socket with plastic shutter
18 Main duct, steel folded spiral-seams duct
19 Connection duct, flexible aluminium duct
AFR 80, Ø 75/80
20 Power cable
37 Mounting support UPM 60/100 (2 items)
38 Plaster protective cover
39 Cable grommet
40 Expanded rubber ER-MO
12.1.4 ER-UP/G wall installation,
single room
1. Take plaster protective cover [38] out of
ER-UP/G housing.
NOTICE
The unit will be damaged and function
impaired if the fixing screws used are
incorrect / too long.
Fixing screws may not penetrate into
ER-UP/G housing. Use screws provided
(mounting support UPM 60/100).
2. Cut the mounting support [37] to the
required length, bend it into shape and fix
it to the ER-UP/G housing with the
supplied fixing screws.
3. Mark fixing holes for mounting support on
rear shaft wall, produce holes and insert
dowels. Suitable mounting material is to
be supplied by the customer.
DANGER
Risk of short-circuits and damage to unit.
If the cable grommet [39] is not installed
correctly, water may penetrate the
ER-UP/G housing. The degree of
protection can no longer be guaranteed.
Drive through cable grommet so that it
can seal the cable sheathing all the way
round (circular, no slots).
4. Insert power cable [20] from rear of
housing through cable grommet [39] into
ER-UP/G housing.
5. Insert ER-UP/G housing with the mounting
support [37] into the shaft and fix it to the
rear wall of the shaft.