17. Extraction socket ER-AS for WC odour extraction
40
17. Extraction socket ER-AS for
WC odour extraction
NOTICE
Extraction socket AS not permitted in
conjunction with ER-UPB or Centro!
ER-UP/G and ER-UPD housing units can be
connected to the WC flushing pipe using the
ER-AS extraction socket. A Ø 70 duct cross
section facilitates low air speeds in the
connecting duct and an effective, draft-free
extraction of odours.
Pre-requirement for the connection
A Ø 70 branch must be installed in the
flushing pipe of the flush-mounted cistern.
Installation
1. Cut the left, right or bottom housing
segment "S" out of ER-UP housing at the
marking using a knife
Fig. 9.
2. Plug ER-AS extraction socket into ER-UP
housing. The edge of the socket must click
into place on the wall of the housing.
CAUTION
Damage to unit in the event of improper
installation position of the housing floor
seal. Protection class is not
guaranteed.
Lift up the housing floor seal before
inserting the ER-AS extraction socket
and then reposition it correctly
afterwards.
3. Install ER-UP/G or ER-UPD housing unit
in accordance with chapters 12.1 and 12.2.
Note the descriptions relating to the
second room connection.
4. Connect connection duct to ER-AS
extraction socket and branch in the cistern
flushing pipe. Make sure the connections
between the connection duct and the
ER-AS extraction socket and the branch
are tight.
5. Install fan insert and cover [15]
chap-
ter 14.
It is important that regulating plate
[16] and filter mat [17] supplied with
the ER-AS are inserted. The cover
must engage audibly when locking.
6. Run function test.
22