7 Housing installation
18
7.2 Installation information for ER-
UP/ G housing
(also
Requirements in line with approval [
and approval)
ER-UP/G are equipped with a plastic housing
without fire protection equipment. The ER-UP/G
housing may be installed in the following installa-
tion positions:
•
Wall installation
With air outlet direction (ex-
haust socket) upwards, to the right, to the left or
to the rear. Installation with mounting support.
•
Ceiling installation and suspended ceiling:
Installation with mounting support.
•
Ceiling installation and non-suspended ceil-
ing
: Mounting directly on the ceiling.
Suitable mounting material is to be provided by
the customer.
The plastic shutter should be prepared ac-
cording to these instructions so that it closes
fully sealed in the installation position.
The housing must be inserted without any dis-
tortion.
Failure to do so will mean that the fan in-
sert cannot engage correctly in the housing and
the degree of protection stated on the rating plate
is no longer ensured.
Break open the housing segment [S] below to use
the ER-ZR second room connection set or the
ER-AS extraction socket.
A toilet seat air extraction unit is connected to the
housing using the ER-AS extraction socket
(DN 75/80).
The toilet seat air extraction unit must not
be connected to the second room connection
socket or the Centro exhaust air element.
Use ER-MO expanded rubber for acoustic insula-
tion of thin ceilings capable of resonance (System
and accessory components).
7.3 Important information about
plastering
• Max. compensable plaster overshoot 7 mm.
• Max. protruding housing edge 20 mm, can be
compensated for with spacing frame DR
60/100.
• Installation at a depth of 50 to 100 mm can be
compensated for with the two-part wall frame
ER-MR.
• The gap remaining between the housing and
shaft must be fully sealed with non-flammable
materials that are resistant to deformation so
that incorrect air is not drawn in.
• Joints between the housing and wall can be
covered with cover frame ER-AR.
We recommend keeping these installation
and operating instructions until final installa-
tion in the housing.
7.4 ER-UP/G wall installation, single