7 Housing installation
20
9. Plaster in housing flush with front edge, note
tile thickness if necessary: Important informa-
tion about plastering.
7.5 ER-UP/G ceiling installation,
single room
6 Protective grille
7 Filter mat, filter class G2
8 Adapter
9 Suction duct, second room connection: flex-
ible aluminium duct AFR 75/AFR 80
10 Installation socket for second room extraction
DN 75/80
13 Housing floor seal
37 Mounting support UPM 60/100 (2 items)
S Housing segment
1. Remove the plaster protective cover from the
housing.
NOTICE The unit will be damaged and func-
tion impaired if the fixing screws used are in-
correctly / too long.
Fixing screws may not penetrate into the hous-
ing.
Use screws provided (mounting support
UPM 60/100).
2. For suspended ceilings, cut mounting support
to the required length, bend it into shape and
fix it to the housing (ER GH wall installation,
single room).
3. Mark fixing holes for mounting support/hous-
ing on ceiling, produce holes and insert dow-
els. Suitable mounting material is to be
provided by the customer.
DANGER Danger of short-circuits and
damage to the unit.
If the cable grommet is not installed correctly, wa-
ter may penetrate the housing. The degree of
protection can no longer be guaranteed.
Drive through cable grommet so that it can seal
the cable sheathing all the way round (circular,
no slots).
4. Guide power cable from rear of housing
through cable grommet into housing.
5. Move housing into desired position and secure
to ceiling with/without mounting support.
DANGER Fire may spread if connection
duct is incorrectly installed.
Only use permitted duct material (
).
Correctly attach connection duct to exhaust
socket.