13 ER-AS extraction socket for WC odour extraction
34
13 ER-AS extraction socket for
WC odour extraction
ER-UP/G and ER-UPD housing units can be con-
nected to the WC flushing pipe using the ER-AS
extraction socket. A DN 70 duct cross section fa-
cilitates low air speeds in the connecting duct and
an effective, draft-free extraction of odours.
Pre-requirement for the connection
A DN 70 branch must be installed in the flushing
pipe of the concealed cistern.
Installation
1. Cut the left, right or bottom housing segment
"S" out of ER-UP housing at the marking using
a knife.
2. Plug ER-AS extraction socket into ER-UP
housing. The edge of the socket must click
into place on the wall of the housing.
NOTICE Damage to unit in the event of im-
proper installation position of the housing
floor seal.
Degree of protection is not guaranteed.
Lift up the housing floor seal before inserting the
ER-AS extraction socket and then reposition it
correctly afterwards.
3. Install ER-UP/G or ER-UPD housing unit in
accordance with these instructions. Note the
descriptions relating to the second room con-
nection.
4. Connect connection duct to ER-AS extraction
socket and branch in the concealed cistern.
Make sure the connections between the con-
nection duct and the extraction socket and the
branch are tight.
5. Install fan insert and cover.
It is important that regulating plate and fil-
ter mat supplied with the ER-AS are inser-
ted. The cover must engage audibly when
locking.
6. Run function test.
14 Fault rectification
Fault finding and repairs only permissible
when carried out by qualified electricians.
DANGER Danger to life from electric
shock.
Prior to accessing the connection terminals,
switch off all supply circuits. Switch off mains
fuse, secure against being accidentally switched
back on and position a visible warning sign.