18 Wiring diagrams
37
18 Wiring diagrams
18.1 Wiring diagrams
ER 60 and ER 100, Centro E, Centro-H
The fan starts up after switching on the room
lighting (with switch S1). The fan also switches off
after the room lighting has been turned off.
ER 100 with Main and Second room connec-
tion
The fan starts up after switching on the room
lighting (with switch S1). The fan also switches off
after the room lighting has been turned off.
ER 60 VZ, ER 60 VZ 15, ER 100 VZ, ER 100 VZ
15
S1 = Switch On/Off
(ON after approx. 50
seconds)
➀ = Main room
➁ = Second room
Standard switching:
The fan starts up approximately 50 seconds after
the room lighting is switched on. The fan has an
overrun time of approximately 6 minutes after
switching off. With VZ 15 units, the overrun time
is approximately 15 minutes.
Switching option
The fan starts up approx. 50 seconds after
switching on the room lighting (with switch S1 and
S2).
The fan has an overrun time of approximately 6
minutes after switching off with switch S1. With
VZ 15 units, the overrun time is approximately 15
minutes. In addition, the fan can be switched off
with switch S2 independent of the room lighting.
ER 60 VZC, ER 100 VZC
The fan starts up after a start delay when the
room lighting is switched on. This can be adjusted
continuously from 0 - 150 seconds. Depending on
the setting, the fan has an overrun time of
between 1.5 and 24 minutes after switching off.
The overrun time can be adjusted continuously
from 1.5 to 24 minutes.
ER 100 VZ and ER 100 VZ 15 with main and
second room connection
The fan starts up approx. 50 seconds after
switching on the room lighting (with a switch). The
fan has an overrun time of approximately 6
minutes after switching off with the last switch to
have been used. With VZ 15 units, the overrun
time is approximately 15 minutes.