6. Operating the fan
9
6. Operating the fan
ER-UP units are usually switched on and off
manually (using a switch), depending on unit
variant and connection variant.
Barrier-free units work as per the automatic
function. Alternatively, these units can be
operated using an optional switch.
Please read chapter 7.3.3 (ER-UP controls)
or contact your installer or planner for details
of the special functions and operating
characteristics.
Control model
standard, EVZ or EG
The fan is switched on and off with a switch
that is to be provided by the customer.
Control model
EH
Barrier-free unit. The fan switches on when
the air humidity limit value is exceeded. No
switch needed. The fan can also be operated
manually using an optional switch
function description in chapter 22.
If the fan is switched on and off
manually, function in accordance
with DIN 18017-3 is not always
ensured.
In the event of thermal overload, the
fan switches off automatically. Wait
until the motor has cooled down.
Cool-down time can be up to 10
minutes. The fan switches back on
automatically after cooling down.
7. Product information
The
ER-UP/GH
recess-mounted housings
are specified for ER recess-mounted versions
with ER 60 E or ER 100 E fan inserts.
Other ER-UP housing types are not permitted
for these fan inserts.
The connection diameter for ER-UP/GH
housings is Ø 75 or Ø 80.
7.1 Installation conditions
If installed in accordance with
DIN 18017-3, use is only permitted:
● in single air extraction systems with a
common main duct.
● with an air supply via shaft or duct.
● with permitted connection ducts.
● with the ER-UP housing and fan insert
suited to the system.
● with recess installation in the wall or
ceiling.
● if installation is undertaken correctly in
accordance with these instructions.
● with sufficient space from the wall or
ceiling.
● if unit is completely installed.
● with the correct air filters.
● with the outside air openings stated in the
planning documents.
If the installation deviates from
DIN 18017-3:
● ER-UP fans can also be used as
standalone units.
● Installation in the wall or ceiling is
permitted.
● ER-100 fans can be used to extract air
from another room (interior kitchen etc.).