ER 60 I, ER 100 I
Standard switching
Switching options
ER 100 RC
ER 60 I, ER 100 I
Interval switching automatically controls the
switching-on of the fan after the defined
interval time, if the fan has not been switched
on during this time. The interval times can be
set to between 1 and 15 hours. The switch-on
time is 10 minutes.
In the case of manual switch-on, the start
delay is approx. 50 seconds and the overrun
time is 10 minutes. The interval function can
be switched off
chapter 14.1.
Standard switching:
The fan starts up approximately 50 seconds
after the room lighting is switched on. The
fan has an overrun time of approximately
10 minutes after switching off.
Switching option
The fan starts up approx. 50 seconds after
switching on the room lighting (with switch
S1 and S2).
ER 100 RC
The fan can be switched on and gradually
upshifted using a radio switch.
Use with RLS RC
Depending on the RLS RC setting, the fans
adopt defined operating statuses.
If using an additional radio switch, the
operating stage selected by this switch is
active for 30 minutes.
Then the operating stage selected by the
RLS RC is adopted. The base load is
permanently activated in the factory using
a DIP switch.