1 Safety
6
1 Safety
• Read through
these instructions
before install-
ation. Follow the instructions.
• Mounting may only be carried out by specialists
who have the necessary knowledge and experi-
ence in ventilation engineering.
• When working at heights, use suitable ladders/
climbing aids and ensure that they are stable.
Ensure that you are standing securely and can-
not lose your balance and that there is no one
under the unit. The applicable accident preven-
tion regulations must be observed. Assembly
areas must be secured against unauthorised
entry, falling objects and falling.
2 Scope of delivery
MS 160
masonry block, these installation instruc-
tions
or
PP 45 RS
shell kit, these installation instructions
3 Intended use
MS 160
masonry block
for installation in exterior
walls with wall thicknesses of 365 ... 490 mm. For
combination with DN 160 wall sleeves (
PP 45
RHK
or
PP 45 RHL
shell sleeve).
PP 45 RS
shell kit
for installation in exterior walls
with wall thicknesses of 365 ... 490 mm. Ac-
cessories for
PP 45 ventilation units
and
PPB
30
ventilation units.
Ensure a horizontal installation position.
4 Product information
•
MS 160 masonry block
with integrated
1°
slope
to the outside
. Bore Ø 167 mm, foaming
areas inside/outside Ø 174 mm, each 40 mm
deep.
Dimensions (H x W x L): 248 x 240 x 490 mm
•
PP 45 RS
shell kit
with integrated DN 160 wall
sleeve and
1° slope
to the outside.
• Cutting marks for standard wall thicknesses 365
mm, 425 mm and 490 mm.
• Fire-proof class B1.
5 Installation example
1 Internal plastering
2 Inside wall
3 Masonry block or shell kit
4 Construction foam or bonding
5 Insulation
6 Shell sleeve, slope to the outside
7 Exterior wall (clinker, plaster etc.)
6 Installation
• When working at heights, use appropriate lad-
ders/climbing aids and have them steadied by a
2nd person. Observe accident prevention re-
quirements.
• Installation is only permitted in walls with suffi-
cient load-bearing capacity (min. 200 kg/m³).
•
PP 45
internal and external covers are fixed in
the masonry block (EPS polystyrene),
PPB 30
internal and external covers are fixed
outside the masonry block in the wall.
Use suitable mounting material that matches
the respective substrate.