9 Commissioning
42
2. Insert
PP 45 HYI
humidity sensor at I2C inter-
face → Arrow.
3. Fit frame. Make sure it locks into position.
The frame has NO protection against twist-
ing. Ensure that sensor opening (hole in frame)
is above the sensor.
4. Start up ventilation system and register humid-
ity sensor in service mode→..
For installation and wiring of an external sensor→
PP 45
/
PPB 30
installation and commissioning
instructions.
9 Commissioning
Basic settings on the room air control are under-
taken in service mode. If connected to
RLS 45 K
,
the commissioning software may also be used.
Switch on ventilation system as follows:
1. Ensure that all ventilation units and system
components are connected to the room air
controls.
2. Remove warning sign from fuse box and
switch on mains fuse. The ventilation units
start up in ventilation level 2.
3. Run function test.
4. Set the desired parameter values in
Service
mode
or using the commissioning software.
Basic settings can be made directly on the
RLS 45 O or RLS 45 K room air control unit.
To do this, select Service mode and set the
desired parameter value. Additional informa-
tion can be found in the online commissioning
instructions (download at www.maico-ventil-
atoren.com). Here you can also download the
commissioning software for the RLS 45 K
control. This provides you with a wide range
of setting parameters for individual system
adjustments.
9.1 Service mode – operation
Starting service mode
+
Press both
buttons for
5 seconds.
Operating
mode LED
flashes. You
are in the 1st
submenu
(number of unit
pairs, ventila-
tion level, etc.)
→ following
chapters.
+
+
Cycle: selecting parameter
You can
switch
between the
sub-menus
by pressing
the button
once.
Flashing oper-
ating mode
LEDs show in
which sub-
menu item you
are*/** → fol-
lowing
chapters.
/
* Illuminated ventilation level LEDs indicate the
parameter currently set.
** For
PP 45 RC
, the red flashing LED indicates
the currently set parameter.
Changing parameter value
Once you
have reached
a certain sub-
menu, the
parameters
can be set
with these
buttons.
Once the para-
meter has
been changed,
the ventilation
level LEDs
flash.
/
Saving parameter value
To save,
press the but-
ton for 2
seconds.
The parameter
value is now
accepted.*/**
+
* The ventilation level LEDs light up permanently
again.
** On RC units, all 3 LEDs light up and then go
out one after another. Parameter value is adop-
ted, service menu is exited.
Exiting service mode
+
Press both
buttons for
5 seconds.
The unit
switches back
to the current
Summary of Contents for PPB 30 O
Page 3: ...Steuerungskonzept PPB 30 3 Steuerungskonzept PPB 30...
Page 4: ...Steuerungskonzept PP 45 RC PPB 30 RC Funk 4 Steuerungskonzept PP 45 RC PPB 30 RC Funk...
Page 29: ...PPB 30 control concept 29 PPB 30 control concept...
Page 30: ...PP 45 RC PPB 30 RC wireless control concept 30 PP 45 RC PPB 30 RC wireless control concept...
Page 53: ...Concept de commande PPB 30 53 Concept de commande PPB 30...
Page 54: ...Concept de commande PP 45 RC PPB 30 RC radio 54 Concept de commande PP 45 RC PPB 30 RC radio...
Page 95: ...Produktdatenbl tter Product data sheets Fiches techniques du produit 95 PPB 30 O...