Table 15. The format and codes of errors  

Error (returned 
command) 

Reasons  

E0000 

1) Internal buffer of device is overflowed 
2) Cannot find <CR> (0x0D) or\and <LF> (0x0A) 
3) Format of command is invalid  

E0001 

1) Unknown command (it does not P- or J-type command) 
2) The device failed to correctly interpret a command 

Table 16. Available parameters and its description 

Action 

R/W 

HEX-
number of 
parameters 

Frequency 
(0,1 Hz) 

Value 

R/W 

0100 

Minimum 

0101 

Maximum 

0102 

Duration 
(0,1 ms) 

Value 

R/W 

0200 

Minimum 

0201 

Maximum 

0202 

Current 
(0,01 А) 

Value 

R/W 

0300 

Minimum 

0301 

Maximum 

0302 

Measured value (0,1 А) 

0307 

Current set 
calibration (0,01%)

1

 

Value 

R/W 

030E 

Voltage (0,1 V) 

Measured value 

0407 

State of the device  
(bit mask) 

Start (Enable) 

0008h 

0700 

Stop (Disable) 

0010h 

Internal current set 

0020h 

External current set 

0040h 

External Enable 

0200h 

Internal Enable 

0400h 

Allow Interlock 

1000h 

Deny Interlock 

2000h 

Deny NTC Interlock 

4000h 

Allow NTC Interlock 

8000h 

 
 
 
 
 
 
 

                                                           
 
 

1

 Default – 100.00% (2710h), calibration range is from 95.00% (251Ch) to 105.00% (2904h). 

Summary of Contents for MBL1500B

Page 1: ...User Manual Before powering on your driver read this manual thoroughly If you have any doubt or suggestion please do not hesitate to contact us Maiman Electronics Saint Petersburg Russia e mail info m...

Page 2: ...v0 0 1 2020...

Page 3: ...ons and weight 3 6 Electrical characteristics 3 7 Electrical characteristics LD power supply channel 3 8 Electrical characteristics TEC 4 9 Typical Performance Characteristics 4 10 Protections 4 11 Co...

Page 4: ...hannel provides current up to 1 5A with noises no more than 10 15 A The TEC channel provides a temperature change from 12 to 40 C with stability 0 01 C TEC contains integrated self adjusted PID contro...

Page 5: ...nect an external emergency switch Allows to connect an external auto protect device e g over temperature switches The laser can only be turned on with shorted Interlock Soft start The soft start funct...

Page 6: ...emperature is exceeded the LD power supply will be automatically turned off After the temperature returns to normal the LD power supply can be switched on again State after switching on After turning...

Page 7: ...Maiman Electronics MBL1500B 6 Controls 12 Front panel Fig 3 Front panel description Back panel Fig 4 Back panel description...

Page 8: ...e 14 TEC cathode 7 n c 15 TEC cathode 8 n c shield chassis ground How to get started 14 When you turn on the MBL1500 without the connected LD the operation and information on the screen will be incorr...

Page 9: ...etting parameters and settings in detail 15 1 The Main screen Fig 7 The Main screen MBL1500 has a duplicate control using buttons and encoder and or touchscreen Button control will be described at fir...

Page 10: ...4 Control with buttons and encoder Use the Left cursor and Right cursor buttons to select the integer or fractional part of the LD current that you plan to change Turn the encoder to change the curre...

Page 11: ...ou need to set a new value clear the input window using the Clear button If you only want to edit the value use the Back space button to remove unwanted symbols Set the required value using the numeri...

Page 12: ...esponds to the required submenu To return to the QCW Setpoint submenu press the Back button To return to the Main menu press the LD Setpoint button Control with touchscreen To go to the submenu tap th...

Page 13: ...nction button 3 Right cursor Moves the change cursor to the right Function button 4 Control with buttons and encoder or touchscreen The TEC Setpoint submenu has the same control principle as the LD Se...

Page 14: ...the Back button to return to the Main menu 15 8 The Settings LD max current screen Fig 14 The Setting LD max current screen Table 9 The Setting LD max current screen submenus description Button Descr...

Page 15: ...ct the memory cell from Memory1 to Memory9 to save the current values and click the Save button To load values move the selection cursor using the Up and Down buttons to the line with the required mem...

Page 16: ...utton 4 Control with buttons and encoder The Memory Keypad screen is available only with a touchscreen Control with touchscreen To go to the Memory Keypad screen in the Memory screen double tap on the...

Page 17: ...Maiman Electronics MBL1500B 16 15 11 The Info screen Fig 17 The Info screen The Info submenu provides general information Tap on the touchscreen or any button to exit...

Page 18: ...arameter Hex number of the parameter For example 0100h 6 space symbol 20h 7 10 New value of the parameter Hex value of the parameter 0000h 11 return carriage symbol CR 0Dh End of the command The devic...

Page 19: ...0 1 Hz Value R W 0100 Minimum R 0101 Maximum R 0102 Duration 0 1 ms Value R W 0200 Minimum R 0201 Maximum R 0202 Current 0 01 Value R W 0300 Minimum R 0301 Maximum R 0302 Measured value 0 1 R 0307 Cu...

Page 20: ...bout parameters that you can change bit mask 0 bit 1 the device supports this option R 0703 1st bit Frequency 2nd bit Duration 3rd bit Current Lock status bit mask 0 bit Reserve R 0800 1st bit Interlo...

Page 21: ...into CW mode or set not zero frequency value to switch the device into QCW long pulses mode If you try to set a value more or less than limits then the value will be rounded to limit Any attempts to...

Page 22: ...cy value Setting a new frequency value frequency value 30 5 Some commands have a full and shortened version The full version is shown in the table and the shortened version is shown by UPPERCASE For e...

Page 23: ...om 0 00 Lower limit MAX Absolute maximum MIN Absolute minimum CURRent REAL Measured value TEC current 0 1 A UPper 0 0 Upper limit MAX Absolute maximum VOLTage REAL Measured value TEC voltage 0 1 V UPp...

Page 24: ...Maiman Electronics MBL1500B 23 Mechanical dimensions 18 All dimensions are in millimeters...

Reviews: