8.0 Flue Options
8.1 Horizontal Flue Systems
Concentric
The maximum equivalent lengths are 4m
(horizontal) or (vertical). Their lengths exclude the standard elbow and flue/terminal assembly (horizontal) and
terminal assembly (vertical).
Any additional "in line"
bends in the flue system must be taken into consideration. Their equivalent lengths are:
Concentric Pipes: 45° bend 0.5 m
93° bend 1.0 m
NOTE
: Flue length is measured from point X to Y as shown.
IMPORTANT
: All flue systems must be securely supported at least once every metre.
Suitable pipe supports are available as accessories.
Horizontal Flue System Examples