INSTALLATION
8.6
Fitting The Flue
HORIZONTAL FLUE
1. The standard flue is suitable for lengths 100mm
minimum to 1m maximum (measured from the edge
of the flue elbow outlet).
Rear Flue:
maximum wall thickness - 900mm
Side Flue:
maximum wall thickness - 870mm
2. Locate the flue elbow on the adaptor at the top of
the boiler. Set the elbow to the required orientation
(rear, right or left).
3. Measure the distance from the outside wall face to
the elbow (Fig. 27). This dimension will be known as
‘X’.
4. Taking the air duct, mark dimension ‘X’ as shown
(Fig. 28). Measure the length of waste material, and
transfer the dimension to the flue duct (Fig. 28).
IMPORTANT:
Check all measurements before
cutting the ducts.
5. Remove the waste from both ducts. Ensure that
the cut ends are square and free from burrs.
6. Remove the flue elbow from the adaptor.
7. Insert the flue duct into the air duct and pass them
through the hole in the wall.
Wall Thickness
(X)
Wall Thickness
(X)
Fig. 27
Waste
(X)
Waste
Fig. 28
Air Duct
Flue Duct