Extraction system not con-
veying pellets
►
Pellet bridge - destroy bridge and make sure
material flows properly
Suction fan unplugged
►
Connect up suction fan
Storage room auger motor
unplugged
►
Connect up storage room motor
13.17 Ashbox full (Fault 5044) – Ash Warning (Fault 5053)
Display:
[5044] PE Ashbox full
Description:
Moter doesn’t reach the normal speed after 3 attempts.
Display:
[5053] PE Ash Warning
Description:
Ash-box nearly full
Cause and Remedy:
Ash-box full
►
Clear ash-box
Ash-box not completely
closed
►
Close ash-box
End-switch defect
►
Replace end-switch
13.18 Ball lock (Smart and Condens only – Fault 5045)
Display:
[5045] PE Ball lock
– Smart and Condens only
Description:
No pellets detected from capacitive sensor (KAP RA)
Cause and Remedy:
Pellet reserves depleted
►
Refill storage-Room / supply tank
Capacitve sensor RA
defect
►
Replace Capacitve sensor RA
13.19 Burner Motor / Ash box full (SMART and Condens only – Fault 5047)
Display:
[5047] Burner Motor /Ash box full
- SMART only
Description:
The alarm text is displayed after the motor has made 3 unsuccessful attempts
to reach the normal speed of the external de-ashing system.
Cause and Remedy:
Ash box is full
►
Empty ash box
Rotation of burner auger
or ash auger is blocked
►
Ensure rotation of auger
13.20 Container cover open (PEB only – Fault 5052)
Display:
[5052] PE Container cover open
Description:
Container cover open (PEB only) – Input AK
Cause and Remedy:
Cover open
►
Close cover
End-switch defect
►
Replace end-switch
13.21 Pellets Warning (Fault 5054)
Display:
[5054] PE 1 Pellets Warning
Description:
Measured pellets capacity (AE2) is below the threshold
Cause and Remedy:
Pellets nearly empty or
empty
►
Fill up with pellets
PE 568 USA 2.0
72
Summary of Contents for PES 20
Page 26: ...PE 568 USA 2 0 26 Setting language date and time at Pelletronic Touch...
Page 32: ...Menu navigation of Pelletronic Touch PE 568 USA 2 0 32 Main Menu...
Page 57: ...Favorite 57 Operating Manual AutoPellet PES 20 32 56...
Page 92: ...PE S K B 36 56 PE 568 USA 2 0 92 Cleaning the boiler every year...
Page 100: ......
Page 101: ......