With gasket in place, set complete flow stopping
tool on top of slide gate valve positioning stopper
tower in correct orientation to deploy stopper.
(Use the arrow indicator on tool to verify direction
of stopper insertion.)
Attach flow stopping tool to top of slide gate valve
using nuts and washers.
Check gasket.
Attach by-pass / vent port, with gasket in place, to
the side of the flow stopping tool using stud bolts.
Make certain port is closed. Check gasket.
Open slide gate valve and check for any leaks in
the stopping tower. Use leak soap if necessary.
Correct any blow-by or leaks before continuing
stopping operation.
Make sure equalization hose is connected to the
slide gate valve to equalize pressure above and
below the slide gate valve.