2.3 Stopping Tool Kit Specifications
2.3 Stopping Tool Kit Specifications
A) Maximum operating pressure of 60 psi (see NOTE in 2.1C)
B) Stopping Case Weights
a) Stopping tool = 116 lbs.
b) Stopping case shipping weight = 260 lbs.
C) Stopping Case Dimensions
a) Stopping tool height with stopper rod completely extended
and gear box cranked to highest position = 12’ 11”
b) Stopping tool height with stopper set = 10’ 7”
c) Storage case = 85-1/2” length x 19-1/2” width x 19-1/2” height
D) Stopping Accessories Case Weights
a) Slide gate valve = 34 lbs.
b) Stopping accessories case shipping weight = 88 lbs.
E) Stopping Accessories Case Dimensions
a) Slide gate valve height = 5” (9-1/2” with bolts)
b) Storage case = 30” length x 28” width x 10-1/2” height
F) By-pass / vent port
a) Full 4” ANSI 150 (3-3/4”) tap size
b) 4” ANSI 150 flange connection
2.4 MDS Inflatable Stopper Specifications
2.4 MDS Inflatable Stopper Specifications
A) Sizes
a) 8.85” – 10.82” (225 mm – 275 mm) Pipe ID [Part #23101357]
b) 9.84” – 12.40” (250 mm – 315 mm) Pipe ID [Part #23101358]
c) 12.40” – 15.74” (315 mm – 400 mm) Pipe ID [Part #23101359]
B) Inflation pressure of 120 psi or 2x system pressure if unable to achieve 120 psi by compressor or nitrogen
C) Design burst pressure of 350 psi
D) Operating temperature range of 5° F (- 15° C) to 140° F (60° C)
E) Maximum temperature range of 158° F (70° C) for up to 30 minutes
2.5 Vent Stack Specifications
2.5 Vent Stack Specifications
A) Height assembled = 112”
B) 1” camlock male coupling
C) Air hose to venturi connection
D) Hose (standard) of 10 m, 1” camlock connection F x F
E) Ground rod included
F) Weight (less hose) = 27 lbs.
G) Air supply and flow capacity rates =
Air Supply
Flow Capacity
Working Pressure
(PSI)
Air Consumption
(ft
3
/min)
Blow Out Volume
(ft
3
/hr)
80
13
24300
120
13
21200