49
Kleiss MCS60-1016 System Manual v.15 June 2020
|
www.MainlineControlSystems.com
Example II – Both Stoppers Positioned Away From Work Area
Example II – Both Stoppers Positioned Away From Work Area
[Illustration of One Side of Work Area]
[Illustration of One Side of Work Area]
STOPPING TOWER DISTANCES
Nominal Pipe Size
A
(
minimum
)
B
L1* = Steel Welding
L2** = PE, CI, and Mechanical
10”
44”
44”
40”
30”
12”
53”
53”
40”
36”
14”
53”
53”
40”
42”
16”
57”
57”
40”
48”
18”
57”
57”
N/A
54”
A = minimum distance between towers
B = stopper length
L1* = distance from stopper/tower to work area - use standard industry & company practices to minimize heat transfer & sparks
reaching the inflatable stopper
L2** = distance from stopper/tower to work area - measurement is a guide only, follow manufacturer’s fitting recommendations