User Manual
Installation:
Please read this manual thoroughly prior to equipment set-up, operation and maintenance.
This unit is intended for use in a temperature-controlled environment less than 75 degrees Fahrenheit and 60% rela-
tive humidity. Malfunction due to improper conditions is not covered under warranty.
Important!!! Please read before Installation
• If the unit has recently been transported on its side, please let the unit stand upright for a minimum of 24 hours
before plugging it in.
• If the shelf has a raised lip, the lip needs to be installed facing up towards the rear of the cabinet to promote
proper air flow. Failure to install the shelves properly is considered user-error and is not covered by warranty.
• Make sure the unit has reached the desired temperature before lading the unit with products. The unit is meant
for keeping cold products cold, not chilling warm products.
• Make sure all accessories are installed (shelves, shelf clips, etc.) before plugging in the unit.
• Make sure that there is proper ventilation around the unit in the area where it will operate.
• Do not attempt to remove or repair any component of the unit. Consult an authorized service technician for
servicing/repair.
• Do not stand inside the unit or hang on doors.
• Please read through this manual in its entirety.
• This refrigerator is designed to perform in a temperature-controlled environment at 60% relative humidity.
The unit should be located away from doors, air ducts, and fans that could disrupt airflow and negatively
impact performance.
Cabinet Location Guides:
• Install the unit on a strong and leveled surface.
- If the surface is uneven, the unit may be noisy.
- The unit may malfunction if the surface is uneven.
• Install the unit in an indoor, well-ventilated area away from doors, air ducts, and fans.
- For best performance, always maintain 6” of clearance on the back of the unit.
- Do not use outdoors. For indoor use only.
- Avoid direct sunlight.
• Avoid installation in high humidity and/or dusty area.
- Humidity above 60% can cause the unit to rust, collect condensation, and may decrease efficiency.
- Dust collected on the condenser coil may cause the unit to malfunction.
- Malfunctions due to temperatures above 75 degrees Fahrenheit, humidity above 60%, or improperly maintained
condenser coil will void the warranty.
• Select a location away from heat and moisture-generating equipment.
• Do not install the unit inside a closet or alcove.
- Ambient temperatures above 75 degrees Fahrenheit may cause the compressor to malfunction.
Position the merchandiser at its final location before removing the shipping skid. There are four bolts at the bottom
of the merchandiser that secure the shipping skid. Keep the unit lifted and remove all four bolts to remove the skid.
Mainstreet Equipment