Installation

Installation

Installation

Installation

3.1

3.1

3.1

3.1 Preparing

Preparing

Preparing

Preparing for

for

for

for Installation

Installation

Installation

Installation

3.1.1

3.1.1

3.1.1

3.1.1 Preparation

Preparation

Preparation

Preparation Tool

Tool

Tool

Tool

Cross

Cross

Cross

Cross screwdriver

screwdriver

screwdriver

screwdriver

Antistatic

Antistatic

Antistatic

Antistatic wrist

wrist

wrist

wrist strap

strap

strap

strap

Wire

Wire

Wire

Wire stripper

stripper

stripper

stripper

Cable needed:

Power

Power

Power

Power cable

cable

cable

cable

Console

Console

Console

Console cable

cable

cable

cable

RJ-45

RJ-45

RJ-45

RJ-45 connector

connector

connector

connector reticle

reticle

reticle

reticle

Device needed:

Configuration

Configuration

Configuration

Configuration terminal

terminal

terminal

terminal ((((can

can

can

can be

be

be

be PC

PC

PC

PC))))

3.1.2

3.1.2

3.1.2

3.1.2 Check

Check

Check

Check C

C

C

Cabinet

abinet

abinet

abinet

Switch can install in the 19” standard cabinet. Device should be installed in frame.

Generally, one switch should install in one frame.

3.2

3.2

3.2

3.2 IIIInstallation

nstallation

nstallation

nstallation S

S

S

Step

tep

tep

teps

s

s

s

Switch can install in the 19” standard cabinet. The process of installation is as follows::

Step 1: Examine grounding and stability of the cabinet. Use screw to fasten hanger to the

two sides of the front board and back board of the switch;

Step 2: Locate switch on the salver of the cabinet. Move it to thesuitable location along

with the slide of the switch. Keep some space between switch and the slide.

Step 3: Fasten hanger to the fixed slide of the cabinet to guarantee the bracket of each

slot and hanger of the switch are fastened to the cabinet

Summary of Contents for SM3100-28TC-AC

Page 1: ...Manual 2011 Maipu Commnunication Technology Co Ltd All Rights Reserved 1 SM3100 28TC AC SM3100 28TC AC SM3100 28TC AC SM3100 28TC AC Installation Installation Installation Installation Manual Manual M...

Page 2: ...t to this document contents and specifically disclaims any implied warranties of merchantability or fitness for any specific purpose Further Maipu reserves the right to revise this document and to mak...

Page 3: ...ghtning 14 2 3 2 3 2 3 2 3 Check Check Check Check Device Device Device Device and and and and Accessories Accessories Accessories Accessories 14 14 14 14 2 4 2 4 2 4 2 4 Tools Tools Tools Tools for f...

Page 4: ...re Failure Failure 20 20 20 20 5 2 5 2 5 2 5 2 Configuration Configuration Configuration Configuration System System System System Failure Failure Failure Failure 20 20 20 20 5 3 5 3 5 3 5 3 Troublesh...

Page 5: ...ing switching SM3100 28TC AC series switches offer 68Gbps switching capacity which entirely fulfills the enterprise customers requirement of designing and implementing unified highly resilient network...

Page 6: ...nd and management management management management Supports a variety of maintenance and management as SNMP SSH TACACS cluster management RMON and CLI which can fully control the various state data re...

Page 7: ...tch is as in following table Indicator Panel indicator Status Meaning Power indicator Power On Power on Off Power off System operating indicator System Flicker System operation normal Always on off Sy...

Page 8: ...H 440 220 44mm Weight 2 7Kg Input voltage AC 100 240V 47 63Hz Temperature 0 50 Humidity 5 95 Rated power supply 40W 5V Output power Max power consumption 18W 1 3 1 3 1 3 1 3 Service Service Service Se...

Page 9: ...level shaping Traffic shaping available on CPU queues Programmable priority to CoS queue mapping Provide two levels of drop precedence per queue SP WRR DRR Upgrading Support Xmodem FTP and TFTP proto...

Page 10: ...Installation Manual 2011 Maipu Commnunication Technology Co Ltd All Rights Reserved 10 restricted Support 802 1x Maintenance Supports debug information output Support PING Supports system log...

Page 11: ...of of the the the the room room room room and and and and the the the the switch switch switch switch Switch Switch Switch Switch can can can can work work work work normally normally normally normal...

Page 12: ...e temperature temperature and and and and humidity humidity humidity humidity when when when when there there there there is is is is no no no no air conditional air conditional air conditional air co...

Page 13: ...owings AC AC AC AC power power power power supply supply supply supply uses uses uses uses TN TN TN TN system system system system and and and and the the the the plug plug plug plug adopts adopts ado...

Page 14: ...equired Installation environment you can open the box However before the formal installation you need to carefully check the packing list of the device within the box of equipment and accessories are...

Page 15: ...icle reticle Device needed Configuration Configuration Configuration Configuration terminal terminal terminal terminal can can can can be be be be PC PC PC PC 3 1 2 3 1 2 3 1 2 3 1 2 Check Check Check...

Page 16: ...ing cooling cooling there there there there should should should should be be be be 1U 1U 1U 1U distance distance distance distance between between between between two two two two installed installed...

Page 17: ...lightning voltage ground can provide protection Use a thick wire and connect the points with the earth grounding resistance is less than 4 ohms If the switch is installed in the cabinet the cabinet al...

Page 18: ...J45 RJ45 RJ45 RJ45 Description Description Description Description Length Length Length Length 1 TX0 1 1 twisted pair 2m 2 TX0 2 3 RX0 3 2 twisted pair 6 RX0 6 4 48V 4 3 twisted pair 5 48V 5 7 0V 7 4...

Page 19: ...s crimped RJ 45 connector which is inserted to Console interface the other end is a connector with DB 9 holes The Console cable is as the following picture The picture of Console cable Table 5 3 Conne...

Page 20: ...Fast Ethernet Switch is on if the system works normally the booting information will be displayed in configuration terminal if there is failure in configuration system it will display nothing or illeg...

Page 21: ...unication Technology Co Ltd All Rights Reserved 21 configuration of terminal such as hyper terminal baud rate is 9600 data bit is 8 and parity check is none stop bit is 1 flow control is none and choo...

Reviews: