background image

S3100 Install Manual (For SM3100-28TC-AC and SM3100-52TC-AC) V4

.0   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2-3 Attaching power cable to MyPower S3100 switch 

1.

 

Insert one end of the power cable provided in the accessory kit into 
the power socket in the back panel of the switch, and the other end to 
the power source socket with overload and leakage protection. 

2.

 

Check if the Power indicator lamp in the front panel of the switch is on. 
MyPower S3100 is self-adjustable according to the input voltage. As 

long as the input voltage is in the range printed on the switch back 
panel, the switch can operate normally without extra adjustment. 

3.

 

The switch will implement self-testing when powered on. 

 

 Caution

The input voltage must be within the required range, otherwise the switch 
could be damaged or operate abnormally. If after being powered on, the 

Power indicator lamp is still off or the self-testing is incorrect, please 
contact your provider or the client-service center. Do not open the switch 

without permission, to prevent accidental loss or physical injury. 

 

 Maipu Confidential & Proprietary Information 

     Page 

19 

of 

19 

 
 

Summary of Contents for SM3100-28TC-AC

Page 1: ...ication Technology Co Ltd No 16 Jiuxing Avenue Hi tech Park Chengdu Sichuan Province People s Republic of China 610041 Tel 86 28 85148850 85148041 Fax 86 28 85148948 85148139 URL http www maipu com Email overseas maipu com Maipu Confidential Proprietary Information Page 1 of 19 ...

Page 2: ...ty or fitness for any specific purpose Further Maipu reserves the right to revise this document and to make changes from time to time in its content without being obligated to notify any person of such revisions or changes Maipu values and appreciates comments you may have concerning our products or this document Please address comments to Maipu Communication Technology Co Ltd No 16 Jiuxing Avenue...

Page 3: ...arance Good Fair Average Poor Accessibility Contents index headings numbering Good Fair Average Poor Evaluate this document Editorial Language vocabulary readability clarity technical accuracy content Good Fair Average Poor Your suggestions to improve the document Please check suggestions to improve this document Improve introduction Make more concise Improve Contents Add more step by step procedu...

Page 4: ...rance 9 Front Panel 9 Back Panel 10 LEDs 10 Device Installation 12 Installation Notice 12 Installation Environment 12 Installation Instructions 15 Security Warnings 15 Preparations for Installation 16 Device Installation 17 Mount Switch onto a Rack 17 Console Cable Connection 18 Power Cable Connection 18 Maipu Confidential Proprietary Information Page 4 of 19 ...

Page 5: ...politan area networks as access equipment but also can meet the demand of medium scale office networks This series of switch has unique network access functions and flexible management of network including MAC binding filtering limiting the number of Mac addresses IEEE802 1Q VLAN PVLAN IEEE802 1x access authentication QoS ACL bandwidth control IEEE802 3ad TRUNK IGMP Snooping broadcast storm suppre...

Page 6: ...SP scheduling This series also supports port security by sorting its traffic according to port VLAN DSCP IP precedence and ACL table Besides it can modify packets DSCP and IP precedence and specify different bandwidths for voice data video to customize different service qualities z ACL MyPower S3100 Intelligent Stackable Secure Ethernet Access Switch supports the complete ACL policy ACL is a mecha...

Page 7: ...rk traffic and meets the requirements of multicast services like multimedia playing remote teaching and entertainment z Multicast VLAN MyPower S3100 Secure Routing Access Switch adds ports of the switch into a multicast VLAN by configuring the multicast VLAN With the IGMP Snooping enabled users of different VLANs can use a same multicast VLAN which restricts the multicast flow within only one mult...

Page 8: ...English Web management provides a remote browsing graphic management interface making management more direct and convenient while enabling immediate check of working state and real time configuration management SNMP management is in accordance with V1 V2C and V3 standard versions supporting Ether Like MIB Bridge MIB and MIB II as well as standard management information libraries such as RMON 1 2 3...

Page 9: ...on condensing z Size SM3100 28TC AC W H D 440mm 44mm 171mm SM3100 52TC AC W H D 440mm 44mm 229mm z Weight SM3100 28TC AC 2 25kg SM3100 52TC AC 3 0kg z Mean Time Between Failure Minimal MTBF 80 000 Hours Product Appearance Front Panel The front panel of MyPower S3100 switch Figure 1 3 Front panel of SM3100 28TC AC Figure 1 4 Front panel of SM3100 52TC AC Maipu Confidential Proprietary Information P...

Page 10: ...tatus description of the LED indictors Table 错误 文档中没有指定样式的文字 1 The LED indicators of the SM3100 28TC AC switch LED Status Description Blink The port is successfully linked and is sending receiving data right now Off The port is down LINK ACT On Successfully linked On The corresponding G port is in 1000M link mode 1000M Indicator Off The corresponding G port is in 100M link mode or down On Power on...

Page 11: ... SM3100 52TC AC switch does not have any 1000M indicator The Link ACT indicator of 100M port is above the corresponding port and the Link ACT indicator of 1000M port is at the right of the corresponding port Maipu Confidential Proprietary Information Page 11 of 19 ...

Page 12: ... it for air circulation z The switch requires a power input ranging from 100 to 240 VAC 50 60Hz z Make sure that the switch is safely grounded in order to avoid electrostatic damage to the device and potential dangers to people z Avoid direct sunlight and keep the switch away from heat sources and strong electromagnetic interference sources z The switch must be stably mounted to a standard 19 rack...

Page 13: ...ure and humidity Please use an air conditioner to cool it up in summer and a heating system in winter Too high a relative humidity will harm the effect of insulation material which may result in electric leakage Sometimes it may also change the mechanical properties of some materials and cause metal corrosion While in too low a relative humidity the insulation spacer may contract resulting in loos...

Page 14: ...e a good grounding keep the environment dust free and maintain a proper temperature and humidity Operators should wear antistatic uniforms straps or gloves Anti interference All kinds of interference no matter from the switch itself or other devices from the outside or the inside will affect its operation in some forms such as capacitive coupling inductive coupling electromagnetic radiation common...

Page 15: ...rs in this manual carefully or participate in concerning technology training before the installation Make sure all materials tools and other items required by the installation are prepared as well as a proper site for installation and debugging z During the installation it is required to use the brackets and screws provided in the accessory kit and proper tools to ensure stability and reliability ...

Page 16: ...vent accidents z Use standard power sockets which have overload and leakage protection to prevent accidents z Check the circuits installation and the working environment for potential dangers and maintain them regularly for the sake of security z Place the emergency power switch in the working site so that the power can be cut off immediately if any accident happens Caution The potential dangers i...

Page 17: ...ernet Access Switch can be mounted onto a standard 19 rack Please follow the steps below to install it Figure 2 1 MyPower S3100 rack mounting 1 Attach the brackets on both sides of the DCS 3950 series with screws provided in the accessory kit 2 Put the bracket mounted switch onto a standard 19 rack Fasten it at a proper location with the screws provided leaving enough space around the switch for g...

Page 18: ...0 switch 1 Attach the console cable provided in the accessory kit to console port of the switch 2 Connect the other side of the console cable to a character terminal PC 3 After powering on the switch and the character terminal configure the switch through the character terminal Caution Please use the console cable and the console commutator of the switch Don t insert it to other ports or insert ot...

Page 19: ...ding to the input voltage As long as the input voltage is in the range printed on the switch back panel the switch can operate normally without extra adjustment 3 The switch will implement self testing when powered on Caution The input voltage must be within the required range otherwise the switch could be damaged or operate abnormally If after being powered on the Power indicator lamp is still of...

Reviews: