background image

1.

Signals  were  transmitted  by  laser  through  optical  fiber.  The  laser  meets  the 

requirement of class I, no harm with normal operation. Do not look directly into the 

fiber port and the end of the optical fiber terminator. 

2.

Dust plugs need to be installed when optical connectors and optical modules are 

not in use. Dust caps need to be installed when optical fibers are not in use. 

3.

The bending radius of optical fiber should be greater than 20 times the diameter of 

the optical fiber. In general, the bending radius should be equal to or greater than 

40mm. 

1.

When using a switch, the voltage can only be input from V1+ and V1-, V1+ connects 

to live wire L, and V1- to neutral wire N. Do not connect from V2+, V2-; pay attention 

to safety and prevent electric shock. 

2.

Power-on  operation:  First  connect  the  power  cord  to  the  power  terminal  of  the 

device according to the definition shown in the figure above, and then power on. 

3.

Power-off operation: first unplug the power plug, and then remove the power cord. 

 

        Warning 

 

 
 
 
 
 
 
 
 
 
 

 

Power input 

Before connecting the power cord, make sure that the ground is connected. Do 

connect the power cord to the power terminal of the device according to the definition. 

 

 

 

 

 

 

 

 

 

Notes 

 

 

 

 

 

 

 

 

 

 

 

MIEN1203-F

 

MIEN2204-2F

 

MIEN2205

 

MIEN2205-F

 

Switch properties

 

Bandwidth

 

                1G

 

Cache size

 

                    748Kbit 

MAC table size

 

        2K

 

Port

 

100M 

Fiber port

 

1*100Base-FX 

2*100Base-FX 

4*100Base-FX 

SC/FC/ST connectors are available

 

100M 

Copper port

 

2*10/100Base-T(X) RJ45 ports

 

5* 

10/100Base-T(X)   

RJ45 ports

 

4* 

10/100Base-T(X) 

  RJ45 ports 

Full-duplex/half-duplex adaptive, supports MDI/MDI-X adaptive

 

Power

 

Consumption 

1.5W@24V 

(MAX)

 

2.3W@24V 

(MAX)

 

1.5W@24V(MAX)

 

DC power input

 

DC12

48V, 

DC48V(36-72V) 

DC9-60V 

DC12

48V, DC48V(36-72V) 

Supports dual power supply redundancy and reverse connection protection

 

AC power input

 

AC85~264V

frequency

47~63Hz

or DC110~370V

 

Mechanical

 

Size

 

118mm×35mm×86mm

L×W×H

(not include din-rail)

 

Installation 

35mm standard din-rail

 

Heat

 

Aluminum alloy single-rib chassis surface scattered

 

IP protection

 

IP40

 

Weight

 

about 0.64kg

 

Working Environment

 

 

Specifications

 