MIEN3024/3026 Rack Mount Industrial Ethernet Switch

- 12 -

PING command examples:
The IP address of computer 1 is 192.168.0.10, and the IP address of

computer 2 is 192.168.0.11. Make sure that the first item "Allow incoming echo
requests" in the ICMP settings of the local connection of the firewall of the two
machines is checked.The operation method is to open the windows protection
in the advanced page of firewall settings, set the ICMP protocol, as shown in
Figure 2-16 below

.

Figure 2-16 ICMP setting interface diagram

Then click Start→Run of Computer 1, and enter cmd or command (cmd

for Win2000/XP system, WIN98/95 the system uses the command) command
to pop up the console window and send ping 192.168.0.11 -l 1000 -t, (-l refers
to the word for sending data packets the number of sections, -t means sending
data continuously), run ping 192.168.0.10 -l 1000 -t in the computer 2 in the
same way. If computer 1 returns Reply from 192.168.0.11: bytes=1000
time<10ms TTL=128, computer 2 returns reply from192.168.0.10: bytes=1000
time<10ms TTL=128, after running for more than 10 minutes, use the CTL+C
command to calculate the packet loss rate as 0,the device is working properly.
As shown in Figure 2-17 below.

Figure 2-17 The result of testing inputting ping computer in CMD

Summary of Contents for MIEN3024

Page 1: ...MIEN3024 3026 Rack Mount Industrial Ethernet Switch User Manual Edition V3 0 Wuhan Maiwe Communication Co Ltd...

Page 2: ...rmation provided by our company in this manual does not represent for corresponding authorization on these information Our company attempts to ensure the accuracy and applicability for the information...

Page 3: ...3026 Rack Mount Industrial Ethernet Switch II Revision history Version Date Reason V1 0 2013 08 Document creation V1 1 2013 11 Modified housing size V2 0 2014 07 Product upgrade V3 0 2015 14 Product...

Page 4: ...with each other frequently inspection is needed Please keep the fiber socket and plug clean Do not look directly at the fiber section when the equipment is working Please keep the equipment clean and...

Page 5: ...ware structure 3 2 1 1 System structure 3 2 1 2 Product configuration 3 2 2 Hardware Installation 6 2 2 1 Installation requirements 6 2 2 2 The equipment installation 7 2 2 3 Cable connection 9 2 2 4...

Page 6: ...th is 8 8G and support 8K entries in the MAC address table 1 2 Product characteristic 1 2 1 Industry Network features Broadcast storm protection Optional 100Base FX different transmission distances di...

Page 7: ...xchange capabilities IEEE standard 802 3 802 3u 802 3x Exchange method Store and forward Flow control Full duplex flow control half duplex back pressure flow control Mac address 8k Transmission distan...

Page 8: ...configuration The MIEN3024 rack mount industrial Ethernet s chassis is the 19 inch 1U structure The whole machine use six side fully enclosed structure The left and right side panels of the chassis ar...

Page 9: ...ng TX of the same remote switch optical interface Below is the 100M fiber connector Ethernet RJ45 connector This switch series has multi 10Base T 100Base TX Ethernet RJ45 ports Each port has adaptive...

Page 10: ...ting to the power supply please confirm whether the power supply is consistent as required to avoid damage to the device Alarm relay The switch power on and power down alarm relay the wiring terminal...

Page 11: ...her network equipment which is going to be connected and whether other equipment is in place Please confirm the following installation requirements Power supply product uses redundant AC220V power sup...

Page 12: ...wires in the same pipe To avoid interference wires with different signal characteristics should be separated We can use the type of signal transmitted in a line to determine which lines should be sepa...

Page 13: ...panel diagram Figure 2 10 shows a schematic diagram of the rear panel of MIEN3026 2S M 24 100M TX and 2 100M FX Figure 2 10 MIEN3026 2S M 24 100M FX and 2 100M TX rear panel diagram The installation d...

Page 14: ...ice interface provided by the industrial Ethernet switch is a 10Base T 100Base TX Ethernet RJ45 interface use a straight through network cable to connect to the terminal device and a crossover network...

Page 15: ...must meet the following conditions Check whether the specifications models and quantities of all cables are consistent with the construction drawing design and contract requirements before laying out...

Page 16: ...s too small it will cause serious loss of the link optical signal and affect the quality of communication 2 3 Testing guide 2 3 1 System self examination All the service port indicators on the front p...

Page 17: ...Start Run of Computer 1 and enter cmd or command cmd for Win2000 XP system WIN98 95 the system uses the command command to pop up the console window and send ping 192 168 0 11 l 1000 t l refers to the...

Page 18: ...to the test computer through a direct connected network cable and sends PING commands to each other Both parties can correctly PING to each other without packet loss At the same time the LINK ACT lam...

Page 19: ...problem as followings Service on line Call technical support office Maintain or replace 3 1 On line service In our website you can get more useful product information and usage methods in the part of...

Page 20: ...optional Model 100M Base FX 10 100M Base TX MIEN3024 0 24 MIEN3026 2S M 2 24 MIEN3024 4S M 4 20 MIEN3024 8S M 8 16 MIEN3024 12S M 12 12 MIEN3024 16S M 16 8 MIEN3024 24S M 24 0 Our company has the rig...

Page 21: ...MAIWE COMMUNICATION CO LTD Add Building 2 Area E Phase ii Optical valley core center No 52 Liufang road East Lake Hi tech Development Zone Wuhan China Phone 027 87170215 16 Fax 86 027 87170217 www mai...

Reviews: