3.
Vent System Termination
Before installing Power Venter, determine location of
vent system termination.
4.
Location of the Fan
To keep the noise level to a minimum, the fan should
be located as far from the appliance as possible.
A storage cupboard, or laundry area are preferred
locations. Permanent access for inspection and
servicing must be provided.
5. All portions of the vent system under positive pres-
sure during operation (on the outlet side of the
Power Venter) shall be designed and installed so as
to prevent leakage of flue or vent gases into a build-
ing.
General Code Requirements
The exit terminal shall be so arranged that flue gases
are not directed so as to jeopardize the safety of
people, overheat combustible structures or enter
buildings, and that proper clearances are maintained.
Always consult your local codes and authorities. In
the absence of such codes follow the current installa-
tion codes for gas burning appliances CSA-B149.1 in
Canada or ANSI Z223.1/NFPA 54 in the US.
Also see Diagram A - Vent Termination Locations.
Power Venter Specifications
Electrical
Motor voltage .................................... 115
Control Circuit Voltage ........................24
Hz ........................................................60
RPM ................................................3000
Watts ...................................................95
Amps ................................................1.26
Thermal Protection ............................Yes
Mechanical
Shaded Pole Motor ...........................Yes
Int. Fan Cooled ................................. yes
Shaft Diameter (inch) ........................313
Bearings .............................. Sleeve Type