32
Vermont Castings Majestic Products DV360/580 Series
20002261
Fig. 59 Remove air shutter from burner pan.
Shutter
Retaining
Screw
Burner Pan
Air Shutter
Front View
CO103
Fig. 62 Remove pilot orifice.
CO106a
Snap Ring
Index Tab
Allen
Wrench
Fig. 61 Remove pilot hood.
CO105a
Pilot Hood
Pilot Bracket
Shutter Retaining
Screw
Slots Covered
Front View
Top View
Fig. 60 Install conversion shutter. Adjust holes and slots.
Burner Pan
Natural Gas
Front View
Holes Open
CO121
Burner Pan
Holes Open
Shutter Retaining
Screw
Slots Open
LP
4. Remove air shutters from burner pan by removing
shutter retaining screw then air shutter. (Fig. 59)
5. Install air shutters supplied in kit on burner pan.
Replace shutter retaining screw. For conversion to
natural gas adjust both air shutters so slots are
covered. For conversion to LP gas, adjust both air
shutters so all slots and holes are visible. Secure
shutter retaining screw. (Fig. 60)
6. Re-install manifold to burner pan.
NOTE: It is not necessary to remove the pilot tube
for conversion.
7. Remove pilot hood by lifting up. (Fig. 61)
8. Remove pilot orifice with allen wrench. (Fig. 62)
9. Install conversion pilot orifice.
10. Re-install pilot hood and be sure to align with index
tab. Installation is complete.
f i r e - p a r t s . c o m
Summary of Contents for DV360
Page 42: ...fire parts com...