Place the 10mm spacer into the floor channel and use it to align the vertical wall 
profile. Push the mitred ends together and use a spirit level to ensure that the wall 
profile is plumb vertical.

 

Mark the screw holes for the vertical profile. Remove the profile, drill 4.5mm holes 
and insert the wall plugs.

 

 

 

Reposition the vertical wall channel and insert the top and bottom screws to hold it 
in place. Insert the rubber strip into the floor channel. Using suction glass lifters, lift 
the glass panel into the channels.

 

Make sure that the panel is plumb vertical. If necessary, use additional short pieces 
of rubber strip in the floor channel to pack it up and take note of their positions. Do 
not use more than 3 thicknesses of rubber in total.

 

   2 

 

   3 

 

Summary of Contents for Monaco

Page 1: ...to undertaking installation check the accuracy of the following against specifications for the particular installation location Verticality and flatness of walls Where wall profiles are used some lea...

Page 2: ...in the required position for the fixed panel If a tray is used preferably position it about 10mm inboard of the edge Ensure that the mitred end is pushed into the corner tape the channel in place and...

Page 3: ...l to ensure that the wall profile is plumb vertical Mark the screw holes for the vertical profile Remove the profile drill 4 5mm holes and insert the wall plugs Reposition the vertical wall channel an...

Page 4: ...forwards in the floor profile but the glass must be inside the vertical wall profile by at least 5mm along its entire height Mark the floor channel at the end of the glass and mark the wall channel a...