Majestic • CKRUBY30, CKRUBY35 Contemporary Kit Instructions • 2542-939 Rev. B • 2/19
TOOLS
Screw gun equipped with 1/4 in. socket or
1/4 in. wrench
3/8 in. wrench
Instructions for optional glass kit, stone kit or log set if
applicable.
Leave this manual with party responsible for use
and operation.
CKRUBY30, CKRUBY35
Models: RUBY30IN, RUBY30IL, RUBY35IN, RUBY35IL
Installation Instructions
CAUTION! Do not install damaged components.
DANGER
HOT GLASS
WILL
CAUSE BURNS.
DO NOT TOUCH
GLASS
UNTIL COOLED.
NEVER
ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
Preparation
CAUTION! Risk of Burns! The fireplace should be
turned off and cooled before contemporary kit is installed.
• Shut off gas supply and disconnect electrical power.
• Remove decorative front, glass assembly, glass seal
plate, lava rock, embers, logs and refractory, if previ-
ously installed.
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
WARNING! Choking Hazard! Keep media out of reach
of children.
Note:
If an optional LINER kit will be used with the CK-
RUBY30/35, the LINER kit instructions will be needed
during installation of the CKRUBY30/35 kit.
Note:
The CKRUBY30/35 is not compatible with fiber
refractory.
WARNING! Risk of Injury! This kit must be installed by
a qualified service technician.
Models
(U.S. or Canada)
Maximum
Input
BTU/h
Minimum
Input
BTU/h
Orifice
Size
(DMS)
Shutter
Setting
CKRUBY30
(NG)
(0-2000 FT)
28,000 19,600
38
1/2 in.
CKRUBY30
(Propane)
(0-2000 FT)
23,000 16,100
.058
in.
Full
Open
CKRUBY35
(NG)
(0-2000 FT)
30,000 21,000
37
3/8 in.
CKRUBY35
(Propane)
(0-2000 FT)
28,000 19,600
1.55
mm
Full
Open
BTU Specifications