background image

Figure 4.37  Exploded View of Entire Assembly for Point of Refer-

ence only

Item

Description

Qty

1

Screw 8-32 x 1/2 PPH BK

1

2

Washer #10 SAE ZN

1

3

Extension Spring

1

4

Timer Mechanical 12 HR

1

5

Slide Assembly

1

6

Timer Arm Assembly

1

7

Timer Door Assembly

1

8

Air Channel Bottom

1

9

Timer Bracket

1

10

Timer Base

1

11

Timer Handle

1

12

Timer Door Retainer

2

13

Air Channel Gasket

1

14

Screw 8 x 12 PPH BK

10

15

Spacer #8 1/4D 7/32L ZN

1

16

HHSS #10 x 1/4D 1/4 L BK

2

13. 

Install the washer and the hairpin clip back on the 

rod.  See Figure 4.36.

Figure 4.36  Reinstalling Hairpin Clip and Washer

14. 

Reinstall the air chamber cover.  See Figure 4.37.

Screws

Figure 4.37  Air Chamber Cover

15. Reinstall the bottom front access panel.

16. Reinstall the spring handle by twisting it to the left 

and pushing it on.

9.  Fan Snap Disc Replacement

1.  Remove the bottom front access panel by lifting it 

up and off.

2. 

Locate the snap disc to the left of the timer assembly.

3.  Remove the wires from the snap disc.  

4. 

Remove the 1/4” bolt using a 3/8” socket along with 

the bracket.

5.  Pull the snap disc out of the bracket.

6. 

Install the new snap disc in the bracket and reinstall 

in the fireplace.  See Figure 4.38.

NOTE:  Remember to reattach the wires.

Bolt

Wires

Figure 4.38  Snap Disc Replacement

27

Majestic • WarmMajic-II Owner’s Manual • 4188-900 • Rev C • 02/20

Summary of Contents for WarmMajic-II

Page 1: ...re or explosion may result causing property damage personal injury or death WARNING HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch...

Page 2: ...Fan Replacement 22 7 Timer Assembly Replacement 23 8 Timer Removal and Replacement 25 9 Fan Snap Disc 27 5 Troubleshooting A FAQs 28 B Troubleshooting Table 30 6 Reference Materials A Service Parts 31...

Page 3: ...s manual for further information It is against federal regulations to operate this wood heater in a manner inconsistent with the operating instructions in the owner s manual SERIAL NO NUMERO DESERE M...

Page 4: ...later than 24 months following the date of product shipment from HHT regardless of the installa on or occupancy date The warranty period for parts and labor for covered components is produced in the...

Page 5: ...nued opera on with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental condi ons inadequate ven la on nega ve pressure or dra ing caused by ghtl...

Page 6: ...ur dealer Majestic is a registered trademark of Hearth Home Technologies WARNING Fire Risk Hearth Home Technologies disclaims any responsibility for and the warranty will be voided by the following ac...

Page 7: ...the hearth extension Room furnishings such as drapes curtains chairs or other combustibles must be at least 4 ft 1219 mm from the open front of the fireplace Combustible materials are materials made...

Page 8: ...teriorated refractory brick deteriorated baffle and other interior components 3 Baffle and Blanket Ensure correct baffle and baffle protection channel place ment replace baffle components if damaged o...

Page 9: ...ULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture d...

Page 10: ...me setting the ACC may not be required Burn dry well seasoned wood NOTICE To establish your settings always begin with the air control all the way to the left to CLOSED and then move it to the right f...

Page 11: ...replace is hot and a good coal bed is established approximately 30 minutes after fuel is lit High Burn Setting The fan may be left on throughout the burn Medium or Medium High Burn Setting The fan sho...

Page 12: ...d can be as much water as it is wood having a moisture content of around 50 Imag ine a wooden bucket that weighs about 8 pounds Fill it with a gallon of water put it in the firebox and try to burn it...

Page 13: ...The chimney shall be inspected at least annually be fore lighting or once every two months during heating season When creosote has accumulated it shall be removed to reduce the risk of a chimney fire...

Page 14: ...box Add 7 to 9 pounds of start up wood 1 3 inch diameter pieces of cord wood by stacking them in a crisscross pattern This will allow for proper air flow Leave door slightly open 2 4 inches see Figure...

Page 15: ...it burn for up to 20 minutes before setting the combustion air control to the desired setting COMBUSTION AIR CONTROL SETTINGS LOW all the way to the left MEDIUM from the low setting go up to 1 2 inch...

Page 16: ...formation regarding operation and troubleshooting Visit www majesticproducts com to find a dealer WARNING Fire Risk DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPTHA OR ENGINE OIL Do NOT...

Page 17: ...chimney top Have the chimney and adjacent structure inspected by qualified professionals Hearth Home Technologies recommends that NFI or CSIAcertified professionals or technicians under the direction...

Page 18: ...eplace to cool completely Remove baffle and ceramic blanket from fireplace before cleaning chimney refer to Section 4 B 5 Baffle Removal and Installation Close the door tightly Remove the top of the t...

Page 19: ...Replace if this condition is present Inspect glass gasket Confirm glass does not move around in glass frame WARNING Risk of Fire DO NOT remove ashes until the fire is out and the fireplace is cold Ash...

Page 20: ...ass and discard Position the new glass with edges evenly overlapping the opening in the front door Replace the glass frames Start screws to secure glass frames to door keeping them loose for adjusting...

Page 21: ...rick until it is flush with the side of the unit Lay bottom bricks in unit Figure 4 4 Fire Brick Configurations Figure 4 3 3 Door Handle Assembly Slide door handle through door Install washer s as sho...

Page 22: ...ner Bolt 1 Remove the bottom firebrick 2 Remove the four 4 5 32 Allen head screws and pry open the access door with a flat blade screwdriver See Figure 4 10 and remove it Figure 4 10 Pry Open Access D...

Page 23: ...handle remove the four 4 screws at each corner of the combustion cover and fish it up and out of the bottom of the fireplace See Figures 4 11 4 12 Handle Figure 4 11 Removal of Combustion Cover Screws...

Page 24: ...hile supporting the air chamber remove the two 2 1 4 20 bolts at each end of it Then pull it down and out the front See Figures 4 19 4 20 1 4 20 Bolts Figure 4 19 Location of Bolts Figure 4 20 Removal...

Page 25: ...e spring handle by twisting it to the left and pulling on it Hold on to the rod as this is being done See Figure 4 28 4 Pull off and remove the hairpin clip and the washer on the rod See Figure 4 28 S...

Page 26: ...e of the timer shaft is facing the opposite side of the linkage timer arm See Figure 4 32 Figure 4 32 D Cut on Shaft 9 Place linkage control arm over timer shaft and tighten set screw Figure 4 33 10 R...

Page 27: ...lling Hairpin Clip and Washer 14 Reinstall the air chamber cover See Figure 4 37 Screws Figure 4 37 Air Chamber Cover 15 Reinstall the bottom front access panel 16 Reinstall the spring handle by twist...

Page 28: ...onry chimney Try holding a burning rolled up newspaper as close to the flue outlet as pos sible for a few minutes then light the paper under the kindling The heat generated from the burning rolled up...

Page 29: ...Outside air closed Overhead fan operating Overhanging tree Bird s nest or leaves in termination cap Structural changes in chimney area Creosote buildup in flue Strong win d s a r o u nd chimney termin...

Page 30: ...ration Check and clean chimney if needed Check door rope for seal Open air controls ACC Smoke in the house during refueling Open air controls ACC to establish a lively coal bed Open doors SLOWLY Add p...

Page 31: ...WARMMAJIC II Beginning Manufacturing Date Dec 2019 Ending Manufacturing Date Active Woodburning Fireplace Part number list on following page 12 19 1 3 4 5 2 10 12 11 9 6 8 7 13 1 13 14 16 15 31 Majest...

Page 32: ...Retainer Side Qty 2 req SRV4184 121 9 Brick Assembly SRV4184 016 Y 9 1 Brick Wrap Qty 8 req SRV4182 101 9 2 Firebrick 13 25 x 3 25 Qty 2 req SRV4182 203 9 3 Firebrick 13 25 x 4 5 x 1 25 Qty 10 req SR...

Page 33: ...e Assembly Right SRV4180 051 a Door Handle Left SRV480 0530 b Washer 3 8 SAE Black Qty 2 req 832 0990 Y c Pin 1 8 x 5 8 Dowel SRV7000 163 d Nut 3 8 16 Lock Pkg of 24 Qty 2 req 226 0100 24 Y e Door Han...

Page 34: ...ide Assembly SRV4184 041 12 2 Air Channel Gasket SRV4184 189 Y 12 3 Extension Spring SRV433 3950 12 4 Timer Mechanical 12 Hour SRV480 1940 Y Chimney Air Kit CAK4A Fastener Pack Chimney Air Kit 13580 F...

Page 35: ...This page intentionally left blank 35 Majestic WarmMajic II Owner s Manual 4188 900 Rev C 02 20...

Page 36: ...ual with party responsible for use and operation Important operating and maintenance instructions included Read understand and follow these instructions for safe installation and operation This produc...

Reviews: