using the power cord provided with the power supply. 

 

Avoiding Damage to the Instrument 

1. Do not attempt to operate the device if it is damaged. 

2. Protect this unit from physical damage, corrosive agents and extreme 

temperatures (direct sunlight etc). 

3. For proper ventilation and safety concerns, keep at least 10 cm of space 

behind the instrument, and at least 5 cm of space on each side. 

4. Do not operate the power supplies in high humidity environments (> 95%), 

or where condensation may occur. 

5. When the power supply series is taken into a cold room environment, the 

unit can be operated immediately. However, when the power supply series is 

removed from the cold room environment, let the unit equilibrate to room 

temperature for a minimum of 2 hours before using it. 

6. Prior to apply any cleaning or decontamination methods other than 

manufacturer’s recommendation, users should check with the 

manufacturer’s instruction to confirm if the proposed method will not damage 

the equipment. 

 

Equipment Operation 

Follow the guidelines below to ensure safe operation of the unit: 

1. It must be checked the displayed figure to see if it is in the normal condition 

for use before using this unit.   

2. NEVER access dangerous chemistry or other material to prevent possible 

hazards of explosion and damage. 

 

Symbols   

The symbols used on MS 250V / MS 300V Power Supply are explained below. 

 

 

Used on MS Power Supply to indicate an area where a potential 

shock hazard may exist. 

Used on MS Power Supply to indicate a warning. Consult the manual 

to avoid possible personal injury or instrument damage. 

 

 

 

Used on MS Power Supply to indicate a disposal instruction. 

DO NOT

 throw this unit into a municipal trash bin when this unit has 

reached  the  end  of  its  lifetime.  To  ensure  utmost  protection  of  the 

global environment and minimize pollution, please recycle this unit. 

Summary of Contents for MP-250V

Page 1: ...MS 250V MS 300V Power Supply Instruction Manual Catalog Nos MP 250V MP 300V www majorsci com service majorsci com Version 01A October 20 2009...

Page 2: ...Cord 1 x MS 250V MS 300V Power Supply Instruction Manual Major Science is liable for all missing or damaged parts accessories within 7 days after customer received this instrument package Please conta...

Page 3: ...MP 250V or MP 300V 1 x MP 250V or MP 300V 1 x US Plug Power Cord or 1 x Euro Plug Power Cord or 1 x UK Plug Power Cord or 1 x Israel Plug Power Cord 1 x MS 250V MS 300V Power Supply Instruction Manua...

Page 4: ...ning 4 Safety Information 5 Product Specifications 7 Product Description 8 Introduction Overview Controls and Features 9 9 10 Installation Instructions 11 Operation Instructions 12 Troubleshooting Gui...

Page 5: ...equipment is operated 1 Read and follow carefully the manual instructions 2 Do not alter the power supply series Failure adhered to these directions could result in personal and or laboratory hazards...

Page 6: ...emperature Avoiding Electrical Shock Follow the guidelines below to ensure safe operation of the unit MS 250V MS 300V power supply series has been designed to use with shielded wires thus minimizing a...

Page 7: ...ds other than manufacturer s recommendation users should check with the manufacturer s instruction to confirm if the proposed method will not damage the equipment Equipment Operation Follow the guidel...

Page 8: ...rs Timer 1 999 mins with alarm continuous Safety Device No Load detection Leakage detection Over temperature protection Over load protection Shrouded plugs and sockets Sudden load change detection Cro...

Page 9: ...ave bench top space Major Science MS 250V power supply and MS 300V power supply both provide Constant Voltage or Constant Current to instruments used in electrophoresis 4 pairs of terminator and the m...

Page 10: ...four pairs of terminator compact size RoHS and CE compliance for safety concerns can deliver accurate and reliable experimental results from one experiment to another Both of them are perfectly design...

Page 11: ...age for the location of the following controls and features MS 250V Power Supply Cat No MP 250V MS 300V Power Supply Cat No MP 300V Front Control Panel 1 Key to increase either Voltage or Current or T...

Page 12: ...the timer 5 Key to select Voltage value 6 Key to select Current value 7 Key to set or select Timer mode Installation Instructions Major Science MS 250V MS 300V Power Supply series is actually an alrea...

Page 13: ...the electrophoresis unit insert the red lead into the red output jack and the black lead into the black output jack 5 Press Key and then press Key or Key to select the suitable voltage 6 Press Key an...

Page 14: ...he LED is flashing Press Key to restart the run 11 Press Key again to stop the unit at any time if necessary 12 When the run is completed operation stops with alarm and the screen shows Press Key to t...

Page 15: ...ot connected to the power supply or to the electrophoresis unit s or there is a broken circuit in the electrophoresis cell Check the connections to the power supply and on your electrophoresis cell to...

Page 16: ...e power supply by turning the Power switch to the on position If you cannot restart the instrument turn off the power disconnect the power cord from the outlet and contact Technical Service Operation...

Page 17: ...inserting a small flat blade screwdriver into the slot below the ON OFF switch Turn the screwdriver to gently pry open the fuse compartment Note The fuse compartment will not open with the power cord...

Page 18: ...ecalibration under normal use The housing may be cleaned with a dry cloth If the unit must be returned for repair contact our SERVICE DEPARTMENT or your local distributor for shipping instruction Orde...

Page 19: ...is embraced within the terms of the warranty All claims made under this warranty must be presented to Major Science within two years following the date of delivery of the product to the customer Manuf...

Page 20: ...19 MEMO...

Reviews: