Range

 

 

Display Range

 

 

Accuracy (sine wave)*1

 

 

600A

 

 

0.0, 0.4-629.9A

 

 

±1.5 %rdg±4dgt (45-65Hz) 

±2.0 %rdg±4dgt (40-400Hz)

 

 

1000A

 

 

570-1049A

 

 

 

K2007R

1000A AC Clamp Meter

Current Sensor

Trigger

Function Switch

Hold Key

V/Ω Terminal

Barrier

LCD

COM Terminal

Wrist Strap

Cap

Barrier of Test Leads

Safety Warnings

This instrument has been designed, manufactured and tested 
according to IEC 61010: Safety requirements for Electronic 
measuring apparatus, and delivered in the best condition after 
passed the inspection. This instruction manual contains warnings and 
safety rules which must be observed by the user to ensure safe 
operation of the instrument and retain it in safe condition. Therefore, 
read through these operating instructions before using the 
instrument.

●  

Read through and understand the instructions contained in this  

 

manual before using the instrument.

●  

Keep the manual at hand to enable quick  reference whenever 

 

necessary.

●  

The instrument is to be used only in its intended applications.

●  

Understand and follow all the safety instructions contained in 

 

the manual.

●  

It is essential that the above instructions are adhered to. 

 

Failure to follow the above instructions may impair the 

 

protection provided by the instrument and test leads, and may 

 

cause injury, instrument damage and/or damage to equipment 

 

under test.

WARNING

Measurement Category

O

 Circuits which are not directly connected to the mains 

power supply.

CAT II

 Primary electrical circuits of equipment connected to an AC 

electrical outlet by a power cord.

CAT III

 Primary electrical circuits of the equipment connected 

directly to the distribution panel, and feeders from the distribution 
panel to outlets.

CAT IV

 The circuit from the service drop to the service entrance, 

and to the power meter and primary over current protection 
device(distribution panel).

This instrument is designed for CAT IV 300V / CAT III 600V. Test 
leads K-7066A with the supplied cap are designed for CAT IV 600V / 
CAT III 1000V and without the caps are for CAT II 1000V.

 

O:  Device which is not
 

directly connected to  

 

the mains power supply

Interior wiring

●  

Never make measurements under the circumstances  exceeding 

 

the designed measurement category and the rated voltage of 

 

the instrument and the test leads.

●  

Do not attempt to make measurement in the presence of 

 

flammable gasses. Otherwise, the use of the instrument may 

 

cause sparking, which can lead to an explosion.

●  

Never attempt to use the instrument if its surface or your hand 

 

is wet.

●  

Do not exceed the maximum allowable input of any measuring 

 

range.

●  

Never open the Battery cover during a measurement. 

●  

To avoid electrical shock by touching the equipment under test 

 

or its surroundings, be sure to wear insulated protective gear.

●  

Never measure current while the test leads are inserted into the 

 

input terminals.

●  

Test leads to be used for voltage. Measurements shall be rated 

 

as appropriate for Measurement Category III or IV according to 

 

IEC 61010-031 and shall have a voltage rating of 600V or 

 

higher.

●  

Barriers on the instrument body and the test leads provide 

 

protection to keep your fingers and hands from touching an 

 

object under test. Keep your fingers and hands behind the 

 

barriers during measurement.

DANGER

●  

Never attempt to make measurement if any abnormal

 

conditions, such as broken case and exposed metal parts are 

 

found on the instrument or test leads.

●  

Verify proper operation on a known source before use 

 

or take action as a result of the indication of the instrument.

●  

Firmly attach the caps to the test leads when performing 

 

measurements in CAT III or higher test environments. When 

 

K2007R and the test leads are combined and used together, 

 

whichever is lower category & voltage to earth either of them 

 

belong to is applied.

●  

Do not rotate the Function Switch if the instrument and the 

 

equipment under test are connected.

●  

Do not install substitute parts or make any modification to the 

 

instrument. For repair or re-calibration, return the instrument to 

 

your local Major Tech distributor

WARNING

●  

Use of this instrument is limited to domestic, commercial and 

 

light industry applications. Strong electromagnetic interference 

 

or strong magnetic fields, generated by large currents, may 

 

cause malfunction of the instrument.

●  

Connect the test leads to the terminals firmly.

●  

This instrument isn't water proofed. Keep away from water.

●  

Do not pull or twist the test leads to prevent the risk of 

 

damage.

●  

Power off the instrument after use. Remove batteries if the 

 

instrument is to be stored and will not be in use for a long 

 

period.

●  

Do not expose the instrument to the direct sunlight, high 

 

temperature and humidity or dewfall.

●  

Use a cloth dipped in water or neutral detergent for cleaning the 

 

instrument. Do not use abrasives or solvents.

CAUTION

NOTE

●   The LCD shows some digits at the AC V and the DC V 
 

ranges even while the test leads are open. In addition, 

 

the LCD shows some digits instead of 0 when short-

 

circuiting the test leads. However, these phenomena 

 

don't affect measurement results.

1. Specifications

Temperature: 23 ± 5°C, Humidity: 45 - 75%

*1 :  when the measured conductor is in the center of clamp 
 

  jaw Guaranteed accuracy : 0.8A -1000A,less than 

 

  1500A Peak  Input protective current :AC1200A

Range

 

 

Display Range

 

 

Accuracy (sine wave)

 

 

 

600V

 

 

 

0.0, 0.6-629.9V

 

 

±1.2 %rdg±3dgt (45-65Hz)

 

±1.5 %rdg±4dgt (40-400Hz)

 

 

 

ACA

ACV

Guaranteed accuracy : 1.0V - 600.0V,less than 900V Peak Input 
protective voltage :AC/DC720V 10 sec

Guaranteed accuracy : 0.0V - ± 600.0V 
Input protective voltage :AC/DC720V 10 sec 
ACV/DCV input impedance : approx. 10MΩ

DCV

Range

 

 

Display Range

 

 

Accuracy

 

 

600V

 

 

0.0-±629.9V

 

 

±1.2%rdg±3dgt

 

 

 

Resistance / Continuity

(Auto-range)

The symbol 

   indicated on the instrument means that the user 

must refer to the related parts in the manual for safe operation of the 
instrument. It is essential to read the instructions wherever the 
symbol      appears in the manual.

 

DANGER is reserved for conditions and actions 

 

that are likely to  cause serious or fatal injury.

 

WARNING is reserved for conditions and actions 

 

that can cause serious or fatal injury.

 

CAUTION is reserved for conditions and actions 

 

that can cause injury or instrument damage.

● Marks listed below are used on this instrument.

 

User must refer to the manual.

 

Instrument with double or reinforced insulation

 

Indicates that this instrument can clamp on bare 

 

conductors when measuring a voltage corresponding 

 

to the applicable measurement category, which is 

 

marked next to this symbol.

 

AC 

DC 

 Ground (Earth)

 

This instrument is subject to WEEE Directive 

 

(2002/96/EC). 

 

Please contact our dealer near you at disposal. 

Guaranteed accuracy : 0.0Ω - 6.000kΩ 
Open-loop voltage : 3V or less
Input protective voltage :AC/DC600V 10 sec

● 

Measuring method : 

Σ

 modulation ●Over-range indication : OL

● 

Measurement cycle : 2.5 times per second 

● 

Crest factor : less than 3 (45-65Hz)

 

Add ±0.5%rdg±5dgt to above specified accuracies. (Applicable 

 

functions :ACA,ACV)

● 

Applicable Standards :

 

IEC 61010-1/ 61010-2-032/ 61010-2-033 (instrument) Pollution 

 

degree 2, Indoor use,Altitude up to 2000m CAT III 600V / CAT IV 

 

300V

 

IEC 61010-031(Test leads Model 7066A)

 

w/ caps CAT IV 600V / CAT III 1000V w/o caps CAT II 1000V

 

IEC61326 (EMC), EN50581 (RoHS) 

● 

Withstand voltage: AC5160Vrms 5sec

 

between current sensor and enclosure or circuit and enclosure

● 

IP rating : IP40 (IEC60529) ●Insulation resistance :

 

>100MΩ /1000V between enclosure and electrical circuit

● 

Operating Temperature and humidity range :

 

0 to 40°C 85%RH or less (no condensation) ACV

● 

Storage Temperature and humidity range :

 

-20 to 60°C 85%RH or less (no condensation) 

● 

Power source : DC3V R03 / LR03 (AAA) ×2 

● 

Current consumption : < 4mA

Range

Display Range

Accuracy

600Ω

6kΩ

Cont.

0.0-629.9Ω

±1.3%rdg±5dgt

0.570-6.299 kΩ

±2.0%rdg±3dgt

0.0-629.9Ω

Bz threshold value <90Ω