8
7
Range
Resolution Accuracy
40.00nF
10pF
+5.0% of rdg + 50 dgts
400.0nF
0.1nF
+3.0% of rdg + 5 dgts
40.00uF
10nF
4.000uF
1nF
400.0uF
0.1uF
+5.0% of rdg + 5 dgts
4000uF
1uF
+5.0% of rdg + 5 dgts
5.6. CAPACITANCE (Auto-ranging)
Maximum Input: 600V DC or 600V AC RMS.
Range
Resolution Accuracy
9.999Hz
0.001Hz
+1.5% of rdg + 5 dgts
99.99Hz
0.01Hz
999.9Hz
0.1Hz
+1.2% of rdg + 3 dgts
9.999kHz 1Hz
99.99kHz 10Hz
999.9kHz 100Hz
10MHz
1kHz
+1.5% of rdg + 4 dgts
5.7. FREQUENCY (Auto-ranging)
Sensitivity: >0.5V RMS while
≤
1MHz ;
Sensitivity: >3V RMS while >1MHz ;
Maximum Input: 600V DC or 600V AC RMS.
Range
Resolution Accuracy
0.1%~99.9% 0.1%
+1.2% of rdg + 2 dgts
5.8. DUTY CYCLE
Pulse width: >100us, <100ms;
Frequency width: 5Hz – 150kHz
Sensitivity: >0.5V RMS
Maximum Input: 600V DC or 600V DC RMS.
Range
Resolution
Accuracy
-20
°
C~+760°C 1°C
+3% of rdg
-4°F~+1400°F 1°F
+5°/9°F
5.9. TEMPERATURE
Sensor: Type-K Thermocouple
Overload protection: 600V DC or AC RMS.