background image

1. Safety Information 

International Safety Symbols

2. Description

 

1.   Flexible current coil 

2.  Range switch

3.  Power switch

4.  Analog voltage output cable

5.  Power indication

6.  Turn knob

 

 
 

 

This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual
for further information.

This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be 
present

Double insulation

Safety Notes

Ÿ

Do not exceed the maximum allowable input range of any function

Ÿ

Do not use when instrument power is off.

Ÿ

Remove the battery if meter is to be stored for longer than 60 days.

Caution

Ÿ

Improper use of this meter can cause damage, shock, injury or death. Read  and understand this 
user manual before operating the meter.

Ÿ

Inspect the condition of the test coil and the meter itself for any damage before  operating the 
meter. Repair or replace any damage before use.

Ÿ

Use great care when making measurements if the voltages are greater than  25VAC RMS  or 
35VDC. These voltages are considered a shock hazard.

Ÿ

If the equipment is used in a manner not specified by the manufacturer, the  protection  provided 
by the equipment may be impaired.

Ÿ

Do not operate meter while Low Battery warning is on. Replace batteries immediately. 

1

2

3

4

5

6

4. Position Error of Clamp

Accuracy and position error assumes centralized primary conductor 
at optimum position ,no external electrical or magnetic field, and 
within operating temperature range.

 

3. Operation

AC Current Measurements 

According to the power switch, turn on the instrument  power 
supply, insert the output line of the meter into  the input end 
of the high precision digital universal  meter with AC voltage 
measurement function.  Pre estimate the size of the current, to 
obtain the  best output signal, to choose a good measurement 
of  gear. Single phase and then measured the ring into  the 
flexible coil, placed in the central position, and  completely 
closed.  This can be converted to obtain the magnitude of the 
current value.

POWER ON
LOW POWER

100mV/A

30A

1mV/A

3000A

10mV/A

300A

VAC

1.0000

VAC

5. Maintenance

 

 

Cleaning and Storage

Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents.
If the meter is not to be used for 60 days or more, remove the battery and store it separately.

Battery Replacement

1. When the battery capacity is more than 2.5V, the power indicator light is green. When the battery   

capacity is about less than 2.5V, the power indicator is red. Need to replace the battery in time.

2. Remove the Phillips head screw that secures the rear battery door
3. Open the battery compartment.
4. Replace two AAA batteries.
5. Secure the battery compartment.

A

B

C

 

Flexible coil

radius (mm)

 

Error

 

Distance from

Optimum(mm)

1.0% 

1.5% 

2.0% 

35

 

50

 

60

 

 

 

 

 

AC Current

50~400Hz
True RMS

 

Function

 

 

30A AC 

300A AC 

3000A AC 

Range 

 

≤30.00A 

30.0A-300.0A 

300A-3000A 

Best Measurement

Range

100mV/A

 

10mV/A

 

1mV/A

 

Output

Voltage

± (3.0% + 5mV) 

± (3.0% + 3mV) 

± (3.0% + 3mV) 

 

Accuracy

6. Technical Specifications

Note:

Ÿ

Accuracy is given as ±(% of r counts of least significant digit) at 23°C±5°C,  with  relative 
humidity less than 80%RH. 

Ÿ

Output Noise: <5.5mV for each range. 

Ÿ

Max. output voltage: 5.8V.

Ÿ

All scale, if the output voltage is greater than 3V, the  results indicate that the  measurement has 
been out of range, not to be used as  indicator assessment.