background image

                                         

Installation,  Operation  and  Parts  Manual 

MJ-TS6600

 

                                                                                                                     

 

 

INSTALLATION INSTRUCTIONS 

4.1 Preparations before installation 

4.1.1 Space requirements 

Refer to 3.3 for the dimensions of the lift. There must also be a clearance of at least 1 meter (about 39”) between the lifting platform and 

fixed elements (e.g. wall) in all lifting positions. There must be sufficient space at the ends of the lifting platform for driving vehicles on and 

off. 

 

 

 

 

 

 

 

 

 

 

 

To stop vehicles colliding with the ceiling, it is advisable to fit an overhead light barrier in low ceiling buildings.   

4.1.2 Foundations and connections   

The user must have the following work performed before erecting the lift.   

 

Construction of the foundation following consultation with the manufacturer’s customer service or an authorized service agent.   

 

Routing of the wiring to the installation location. Refer also to the corresponding information on the name plate and in the operation 

instructions. Before doing electrical connection, make sure the lift is electrically adapt to the local power supply.   

 

The user must provide fuse protection for the connection. Requirements for power supply cable of the installation site: at least 

2.5mm

2

 (1/8 sq. inch)wire core for 3Ph power and 4.0mm

2

 (3/16 sq. inch)wire core for 1Ph power. 

 

Attention: electrical system connection must be done by licensed technicians. 

4.1.3 Tools and equipment needed for installation   

Tool name 

Specification 

Qty 

Open spanner 

D17-19 

Adjustable spanner 

bigger than D30 

Cross socket screw driver   

PH2 

Lift device 

Capacity more than 1100 lbs. 

Socket spanner   

D6 

 

Summary of Contents for MJ-TS6600

Page 1: ...atform Scissor Lift Mid Rise Lifting Capacity 6600 lbs Distributed by Please read this entire manual carefully and completely before installation or operation of the lift Installation Operation and Pa...

Page 2: ...IONS 8 3 1 General descriptions 8 3 2 Construction of the lift 8 3 3 Dimensions 8 3 4 Technical data 8 INSTALLATION INSTRUCTIONS 9 4 1 Preparations before installation 9 4 2 Installation attentions 10...

Page 3: ...er domestic legislation The reproduction or disclosure of instructions or an extract thereof is prohibited and offenders are liable to prosecution MAJOR reserves the right or initiates criminal procee...

Page 4: ...rson to perform checking It must be ensure that the person chosen satisfies the requirements The user bears special responsibility if employees of the company are appointed as experts or qualified per...

Page 5: ...ned 1 3 10The lift is simply designed to lift the entire body of vehicles with its maximum weight within the lifting capacity 1 3 11 Always insure the safety locks are engaged before any attempt to wo...

Page 6: ...ushing In the event of excessive vehicle weight incorrect mounting of the vehicle or on removing heavy object there is a risk of the vehicle falling off the lifting platform or tipping up Safety measu...

Page 7: ...ge The narrow base heavy weight and large size of the packs make stacking difficult and potentially dangerous If stacking is unavoidable use all appropriate precautions never stack to more than 2 mete...

Page 8: ...e to move easily in your workshop when it is unloaded Being powered by an electro hydraulic system the gear pump delivers hydraulic oil to oil cylinders and pushes upwards their pistons to raise the l...

Page 9: ...ation following consultation with the manufacturer s customer service or an authorized service agent Routing of the wiring to the installation location Refer also to the corresponding information on t...

Page 10: ...Lifting pad TS6600 A03 B06 4 2 4 Hex socket cylinder head screw M6 20 M6 20 20 2 5 Circlip M17 M17 4 2 6 Nylon clip 4 200 4 3 Control unit 1 3 1 Power unit TS6600 A06 B01 1 3 2 Release handle TS6600 A...

Page 11: ...p 1 Remove the packaging and take the mechanical and hydraulic assembly to the designated installing place Please do read and understand this manual thoroughly before next step Step 2 Fix the portable...

Page 12: ...Installation Operation and Parts Manual MJ TS6600 12 Step 4 Connect the oil hose Connect the fitting of oil hose with its tie in on the hydraulic block Step 5 Connect external power supply...

Page 13: ...is below 18 degree Celsius Change the oil 6 months after initial use and change once per year thereafter Step 7 Trial running After reviewing these instructions get familiar with lift controls by runn...

Page 14: ...If max lifting height is 47 1 4 11 If safety advices name plate and logos are clear OPERATION INSTRUCTIONS 5 1 Precautions 5 1 1 Check all connections of oil hose Only when there is no leakage the li...

Page 15: ...ratches will be left due to long time use Raise the lift Make sure vehicle is neither front nor rear heavy and center of balance should be midway between adapters and centered over the lift 1 Make sur...

Page 16: ...d Clean or make adjustment Damaged gear pump Replace it Too low oil level Add oil The hose connection is loose Tighten it The cushion valve is not well screwed up or jammed Clean or make adjustment Pl...

Page 17: ...asualty Check whether oil hose is well connected and whether it leaks or not Check the electrical system Check if safety teeth and safety block matched well or not 6 2 Weekly checking items Check the...

Page 18: ...ion Specification Qty M 320205005 Motor YLX80L2 110V 1 65KW 1PH 60HZ 1 KM 320901031 AC contactor NC1 1810 AC110V 60HZ 1 SB1 320401011 Button AR22F0R 10 W 1 QF 320802004 Circuit breaker NB1 63D32 2P 1...

Page 19: ...y 1 207102029 Y seal ring UN 70 55 10 1 2 207101024 Type O seal ring 23 6 3 55 1 3 207105016 Dust proof ring DH38 1 1 oil tank 2 oil sucking filter 3 gear pump 4 coupling 5 motor 6 composite hydraulic...

Page 20: ...60HZ 1 65kW 1 2 624001064 Rubber oil hose L 3500mm 1 3 615033012 Cylinder 2 TS6600 A05 B01 1 4 310101010 Straight connector G1 4 G1 4 2 5 624001847 Rubber oil hose L 200mm 2 6 615006003 Three way conn...

Page 21: ...Installation Operation and Parts Manual MJ TS6600 21 POS Code Description Specification Qty 1 330405014 Oil tank 6L 1 2 330101004 Hydraulic block YF 2 1 3 330304001 Overflow valve EYF C 1...

Page 22: ...6 30 4 9 330201003B Gear pump For motor specified 110V 1 65KW 1PH CBK F210 CBK 1 0F 10 310101003 Straight connector M14 1 5 G1 4 1 11 330404001 Coupling YL A 1 12 330401001 Oil sucking tube YX BL 170...

Page 23: ...04 4 5 410330151 Pin shaft TS6600 A01 B05 2 6 410330121 Down shaft of oil cylinder TS6600 A01 B06 2 7 410330191 Shaft of the down wheel TS6600 A01 B07 2 8 410330411B UP shaft of oil cylinder TS6600 A0...

Page 24: ...spring 6435B A4 B30 2 29 420040040 Square lifting pad 6254E A7 B2 4 30 420040250 Round lifting pad 6254E A7 B4 C4 4 31 420210060B Padding block 6603B A5 B6 2 32 204301007 Circlip M20 4 33 203103011 Fl...

Page 25: ..._M90X43 2 4 Power unit 110V 1PH 60HZ 1 5KW 1 5 204301004 Circlip D15_GB894_1 2 6 420480080 Handle sheath D22X100 2 7 204201004 Spring washer D8_GB_T93 8 8 204101005 Flat washer D8_GB_T97_1 8 9 6150480...