56
MANUAL LIGHTING INSTRUCTIONS
Empty the repot completely.
Place a half cup of new pellets in the repot.
Drop in a lighted match onto the pellets.
Carefully replace all interior components. Avoid the re, don't get
burned.
Turn the grill on and cook as normal.
Contact MAK Grills for a replacement igniter.
If your igniter fails, you can still start your grill:
Pour two tablespoons of hand sanitizer over the pellets and stir.
Wait ve minutes for the re to establish.
AUGER IS NOT TURNING
Cause: Indicates auger is jammed or has failed.
The auger works on a timed interval basis depending on the
temperature setting on the Pellet Boss. During start-up the auger
will run for approximately three minutes. It then may shut off for a
specied period of time depending on the temperature reading
inside the grill, then continue to run again.
Empty the pellet hopper to see if your pellets have been exposed
to moisture. If they have absorbed moisture or water, they will
swell and jam your auger.
FAN DOES NOT RUN
Cause: Indicates fan blades are obstructed, fuse has blown, or fan
has failed.
The fan should run whenever the grill is on.
If it does not, unplug the grill and remove the fan panel.
Unplug the FAN wire into the blue receptacle; be sure the
connection is secure.
Check fan blades for obstructions such as pellets or rocks.
Remove debris.
Check the fuse on the back of the Pellet Boss. If it is blown,
replace it with a 4-amp fuse.
TROUBLESHOOTING & REPAIRS